background image

3

Cabinet Preparation

The cutout depth should be 24

 

The cutout dimensions shown allow for a full door swing and access to the pull-out racks when 

installed as a built-in in standard 24

 deep cabinets.

• 

The wine chiller, wine reserve and beverage center can be installed freestanding.

•   If installing between frameless cabinets, a 1/2

 wide filler strip or side panel may be 

needed on hinge side. The filler strip will act as a spacer between the case and adjacent 

cabinet door swing.The width of the opening must include the filler panels. 

NOTE: 

The front face of the chassis should be even with the adjacent cabinetry.

SIDE-BY-SIDE INSTALLATIONS

Increase storage capacity by installing two beverage centers or wine chillers together.

• 

 A side-by-side installation requires at least a 47-1/2″ wide opening. No trim kits required. 

•   Products must operate from separate, properly grounded receptacles.

STACKED INSTALLATIONS

Increase storage capacity by installing two beverage centers or wine chillers together.

•   A stacked installation requires at least a 23 3/4” wide opening. No trim kits required.

•   A cutout height of 34 1/2” - 35” is required.

•   A minimum of 2” rail is required between units.

•   A 3/4” or better support platform must be provided for the upper unit.

•   Products must operate from separate, properly grounded, receptacles.

Electrical Power Supply 

Requirements

NOTES:

1.  If the power supply 

requirements shown do 

not agree with those listed 

on the product data plate, 

provide a power source per 

the information found on the 

product data plate. 

2.  If the electrical service 

provided does not meet the 

product specification, or 

does not conform to the NEC 

or local standards, do not 

proceed with the installation.  

Call a licensed electrician to 

correct the electrical service 

before proceeding.

3.  Be certain to locate the 

electrical receptacle in an 

accessible location, so that 

the appliance may be easily 

unplugged in the event that 

service becomes necessary. 

4.  Do not use an extension cord 

to connect the appliance to the 

electrical receptacle.

5.  It is the owner’s responsibility 

to ensure that electrical 

installation of this appliance is 

 

performed by a qualified 

electrician. The electrical 

installation must comply 

with the National Electric 

Code ANSI/NFPA 70-1990 (or 

to latest revision) and local 

codes and ordinances.

6.  GFI (ground fault interrupter) 

is not recommended

Electrical Supply Requirements

  120VAC, 60 Hz, 15A Dedicated Circuit

  Appliance is supplied with a 48” (1219mm) 

power cord with a three prong grounded 

plug.

Total Connected Load

 

.01kW (1.2A)

Locate

Outlet

10 1/2”

(267mm)

9“ Max.

(229mm)

24”

(610mm)

34 1/2” - 35”

(876mm - 889mm)

1 1/2”

(38mm)

23 3/4” Min.

(603mm)

Locate Outlet

24”

(610mm)

1 1/2”

(38mm)

47 1/2” Min.

(1207mm)

15”

(381mm)

10 1/2”

(267mm)

10 1/2”

(267mm)

9“

(227mm)

34 1/2” - 35”

(876mm - 889mm)

Summary of Contents for Wine Steward/Beverage Cooler

Page 1: ...2 Cabinet preparation Page 3 Electrical power supply requirements Page 3 Staining wood drawer fronts Page 4 Reverse door swing Page 4 Applying Dacor Nameplate Page 4 Installing Toekick Page 4 Levelin...

Page 2: ...s appliance if it has a damaged electrical cord or plug if it is not working properly or if it has been damaged or dropped 7 This appliance should be serviced only by qualified service personnel Conta...

Page 3: ...et cutout dimensions must be used as indicated All contact surfaces between the appliance and the cabinet must be solid and level Make certain that you have everything necessary to ensure a proper ins...

Page 4: ...e properly grounded receptacles Electrical Power Supply Requirements NOTES 1 If the power supply requirements shown do not agree with those listed on the product data plate provide a power source per...

Page 5: ...ndle will be on the right side of the door hinges will be installed on the left side of the case Remove the door stop and cam riser on the original bottom right side of the door Remove the fill plug o...

Page 6: ...rage must be supplied to the electrical receptacle from a grounded single phase circuit that is protected by a properly sized circuit breaker or time delay fuse The required voltage frequency and ampe...

Page 7: ...6 NOTES...