background image

Summary of Contents for 3000

Page 1: ......

Page 2: ...t has been made to ensure that the information in this manual is accurate Wine Enthusiast is not responsible for print ing or clerical errors Wine Enthusiast reserves the right to make corrections or...

Page 3: ...ned by the customer and cannot be warranted by Wine Enthusiast Quick Reference Guide Introduction Receiving Inspecting The Unit Preparing the Wine Cellar Installation Pre Installation Preparing the In...

Page 4: ...age 2 WE 081313 N FINITY QUICK REFERENCE GUIDE Front Side View Rear Side View Controller Front Drain Port Power Cord front location optional Power Cord rear location standard Air Sensor Rear Drain Por...

Page 5: ...r box and all packaging materials They provide the only safe means of transporting shipping the unit RECEIVING INSPECTING THE UNIT Thank you for purchasing an N FINITY cooling unit We strive to provid...

Page 6: ...r the better it will be at maintaining a consistent temperature Insulation Insulation is REQUIRED with the use of the N FINITY product Standard fiberglass or rigid foam insulation is normally used in...

Page 7: ...ft clearance in front of the cooling unit This will assure that the unit can move the air around in an efficient manner Avoid any attempt to camouflage the unit by installing racking in front of the u...

Page 8: ...transporting the unit Place the N FINITY system on a tabletop to prepare it for installation and testing Plug system into a live electrical outlet and turn unit on The system may take up to 10 to 15 m...

Page 9: ...make the same hole on the other side of the wall Since you already have one hole this is an easy process Using a nail mark all four corners of the first hole by making nail holes through the sheetroc...

Page 10: ...te support for the unit 5 Seal all cracks and gaps around the unit on the cellar side with an air tight sealant and caulking to prevent air leakage The hole that the unit is installed through is basic...

Page 11: ...h a front and rear Drain Line Port This allows you to choose if you would like to have excess condensate drain back into the cellar for additional humidity Simply remove the cap from the Drain Port yo...

Page 12: ...Set point is displayed by default The air sensing probe temperature can be accessed by pushing the set button and scrolling through PB1 and set point parameters Safety Features Once the compressor re...

Page 13: ...he set button when SEt is displayed on the screen The current set point will be displayed Use the up or down arrows to change the set point to the desired temperature Press the set button again once t...

Page 14: ...is not in cooling mode the snowflake symbol will not be lit 2 Add heat to the room until the wine reaches the desired temperature Press and hold the set button for approximately 5 seconds to enter the...

Page 15: ...Page 13 VERSION 2 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Page 16: ...he refrigeration system to equalize prior to starting the compressor Defrost Cycle The Defrost Cycle is a precautionary measure as icing or frosting of the coil does not occur during normal operation...

Page 17: ...r then energizes the compressor relay which activates the compressor evaporator fans and condenser fans The unit provides cooling until the air sensor probe senses the set point At this point the comp...

Page 18: ...Page 16 WE 081313 VERSION 1 CONTROLLER WIRING SCHEMATIC...

Page 19: ...ith a vacuum If coil is very dirty use a small hand spray with a small amount of liquid dish washer detergent Spray coil let set for 5 min then flush with fresh water Remove blockage Call a service te...

Page 20: ...air flow out If compressor runs check for and clean condenser coil as possible cause of compressor overheating If problem repeats call Technical Support Solution Call Technical Support at 800 648 6058...

Page 21: ...ries Unit Location of unit and installation details such as ventilation ducting construction of your wine cel lar and room size Contact Wine Enthusiast Customer Service Wine Enthusiast Companies 333 N...

Page 22: ...ge in which Wine Enthusiast states these Terms and Conditions is English Wine Enthusiast reserves the right in its sole discretion to change these Terms and Conditions at any time for any reason witho...

Page 23: ...t read the Wine Enthusiast Owner s Manual and thereafter the End User must follow the required installation use and maintenance procedures set forth by Wine Enthusiast in N FINITY s Owner s Manual The...

Page 24: ...ecurity interest in each Product until payment in full c Every provision of these Terms and Conditions shall be construed to the extent possible so as to be valid and enforceable If any provision of t...

Page 25: ...Page 23...

Page 26: ...Wine Enthusiast Companies 333 North Bedford Rd Mt Kisco NY 10549 www wineenthusiast com...

Reviews: