5.3 

 Instructions for assembly: 

Remove the tank cover, releasing the 6 clips(229). The maximum level reached in the tank with the 
standard float is 285 mm from the tank bottom. If it is necessary to maintain a lower maximum level, 
the standard float must be replaced with the float type B (standard supply) (fig. page 12 ). With this 
float it is possible to limit the maximum level of water in the tank to 110 mm. A typical application is 
for a shower drain. To change the float, slacken the screw (26) and extract the standard float from the 
horizontal pin onto which it is keyed, fit the float type B, performing the same operations in inverse 
order, and secure it with the same screw..

 

 

 

Insert the pump between the two anchoring points on the bottom of the tank and make the following 
hydraulic connections:

 

 

 

INPUT:

 

(for the input references, see the example of installation on page 41)

 

 

 

 

2 on sides A and B: to use these inputs a hole must be made in the box on the marks and the 
adapters (119) must be fitted for PVC pipes with external diam. = 40 mm, or internal diam. = 50 
mm, to be glued on with adhesive type “TANGIT” (HENKEL). The gaskets (64a) must be 
applied on the outside of the tank. 

 

1 on side C: to use this inputs a hole must be made in the box on the mark and the ¾” hosetail 
(119a) must be fitted for rubber pipes with external diam. = 25 mm. The gasket (64b) must be 
applied on the outside of the tank. It is recommended to secure the pipe to the sleeve with two 
hose-clamps. When used for a washing machine drain, install a siphon (not supplied) between the 
machine and the collecting tank, so as to avoid the overflow of liquid when it is not in use. 

 

1 on the cover D: for pipes with external diam = 30 or 40 mm. To use this input, make a hole in 
the cover in the place provided, without damaging the seat of the rubber sleeve. Use one of the 
clamps (84) or (84a) supplied in the accessories kit to ensure the seal between the input pipe and 
the cover.

 

 

 

DELIVERY:  

 

 

Fit the no return valve (137) supplied in the accessories kit, screwing it onto the output mouth, after 
fitting the sealing gasket (64a) between the tank and the valve. Tighten it to ensure the seal of the 
gasket. Directly connect the delivery pipe with internal thread 1¼” or fit the connecting union (161) 
to use a rubber delivery pipe with internal diam. = 32 mm, to be secured with a hose-clamp. 

 

 

 

Before replacing the cover on the tank, test the connection with clean water, after having connected 
the pump to the mains. 

 

 

 

VENTILATION:  
The ventilation duct E may be made using a PVC pipe with external diam = 30 or 40 mm, to be 
connected to the cover of the tank with a rubber clamp (84) or (84a) supplied as standard in the 
accessories kit. Avoid horizontal stretches. If it is not possible to make a pipe, the seat for pipe 
connection may be fitted with a valve with filter. To fit the valve, refer to the diagram on page 12 and 
insert all its components in the valve housing, proceeding in this order: float ball (49), seal ring (16a), 
safety valve support disc (180), O-Ring (95), rubber clamp diam. 490 mm (84a), breather cap   (26). 

 

 

6.   IMPORTANT 

 

 

6.1 
 
 

 

Install the tank in a position protected against frost.

 

6.2 
 
 

 

The tank may stand on the floor or be placed in a masonry pit. In any case the surface on 
which it rests must be perfectly horizontal and the whole of the bottom of the tank must rest 
on the surface.. 

 

6.3 
 
 

 

Ensure that the difference in level between the pump and the sewage mains is compatible 
with the pump performance.

 

6.4 

 

The tank should be ventilated in any case.

 

 
 
 
 
 
 
 

Summary of Contents for NOVA

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE INSTALLATIONSANWEISUNG UND WARTUNG INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UND...

Page 2: ...ements for Pumps EN 12050 1 03 Lifting plants for wastewater containing faecal matter DE EG KONFORMIT TSERKL RUNG Wir DAB Pumps S p A Via M Polo 14 Mestrino PD Italy erkl ren unter unserer ausschlie l...

Page 3: ...1 65 EU Restriction of the use of certain hazardous substances in electrical and electronic equipment i cu urm toarele norme EN 60335 1 10 Household and Similar Electrical Appliances Safety EN 60335 2...

Page 4: ...ITALIANO pag 01 FRAN AIS page 05 ENGLISH page 09 DEUTSCH seite 13 NEDERLANDS bladz 17 ESPA OL p g 21 SVENSKA sid 25 29 ROMANA pag 33 ESKY strana 37...

Page 5: ...una sorveglianza o di istruzioni riguardanti l uso dell apparecchio I bambini devono essere sorvegliati per sincerarsi che non giochino con l apparecchio 1 3 Verificare che l impianto non abbia subito...

Page 6: ...supervised to ensure that they do not play with the appliance 1 3 Check that no damage has been done during transport or storage In particular ensure that the external casing is perfectly entire and...

Page 7: ...n the cover D for pipes with external diam 30 or 40 mm To use this input make a hole in the cover in the place provided without damaging the seat of the rubber sleeve Use one of the clamps 84 or 84a s...

Page 8: ...t from the delivery duct unscrewing the two ring nuts of the elbow connections 161a 7 4 It is recommended to clean the system at least once a year with running water operating the pump repeatedly 7 5...

Page 9: ...GASKET 119a STRAIGHT HOSETAIL 25 180 VALVE SUPPORT DISC 229 CLOSING CLIP 161 STRAIGHT HOSETAIL 1 32 95 O RING 3143 36 14 2 62 118 NIPPLE 1 88 RUBBER CABLE CLAMP 26 BREATHER CAP 161a CURVED HOSETAIL 1...

Page 10: ...LOTTEUR DOUCHE ASSEMBLY DIAGRAM SHOWER FLOAT KIT MONTAGESCHEMA KIT SCHWIMMER DUSCHE MONTAGESCHEMA SET VLOTTER DOUCHE ESQUEMA DE MONTAJE KIT FLOTADOR DUCHA MONTERINGSSCHEMA FLOTT RSATS DUSCH SCHEMA DE...

Page 11: ...O DI INSTALLAZIONE EXEMPLE D INSTALLATION EXAMPLE OF INSTALLATION INSTALLATIONSBEISPIEL INSTALLATIEVOORBEELD EJEMPLO DE INSTALACION INSTALLATIONSEXEMPEL EXEMPLU DE INSTALARE P KLAD INSTALACE MIN 130 D...

Page 12: ...43...

Page 13: ...ernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 PUMPS AMERICA INC DAB PUMPS DIVISION 3226 Benchmark Drive Ladson SC 29456 USA info usa dwtgroup com Ph 1 843...

Reviews: