中
文
75
−
电机制造
:
符合
CEI 2-3 1110
手册标准
−
重量
:
见包装标签
−
尺寸
:
见
92
页表格
保险丝和调幅等级
:
指示值
(
安培
)
型号
保险丝
3 x 230V 50/60Hz
3 x 400V 50/60Hz
K 36/200 T; K11/500 T; KE 36/200 T;
12
8
K 40/200 T; K 18/500 T; K 55/100 T; KE 40/200 T; KE 55/100 T;
15
8
K 55/200 T; K 28/500 T; K 66/100 T; K 90/100 T; KE 55/200 T; KE 66/100T; KE 90/100 T;
20
12
K 40/400 T; KE 40/400 T;
25
12
K 70/300 T; KE 70/300 T;
25
16
K 50/400 T; K 30/800 T; K 40/800 T; K 20/1200 T; KE 50/400 T; KE 30/800 T;
KE 40/800 T;
K 25/1200 T; K 70/400 T; K 80/300 T; KE 25/1200 T; KE 70/400 T; KE 80/300 T
40
20
K 50/800 T; K 35/1200 T; K 80/400 T; KE 50/800 T; KE 35/1200 T; KE 80/400 T;
40
25
-
电线夹钳
:
PG 13,5 K 36/200 T - K 40/200 T - K 55/200 T - K 11/500 T - K 18/500 T - K 28/500 T - K 55/100 T - K 66/100 T
K 90/100 T - KE 36/200 T - KE 40/200 T - KE 55/200 T - KE 55/100 T - KE 66/100 T - KE 90/100 T
PG 21
K 40/400 T - K 50/400 T - K 30/800 T - K 40/800 T - K 50/800 T - K 20/1200 T - K 25/1200 T K 35/1200 T 70/300
T - K 80/300 T - K 70/400 T - K 80/400 T - KE 40/400 T - KE 50/400 T - KE 30/800 T - KE 40/800 T - KE 50/800 T -
KE 25/1200 T - KE 35/1200 T - KE 70/300 T - KE 80/300 T - KE 70/400 T - KE 80/400 T
供电电缆线要有一个不低于下面表格所示数据的额定剖面面积
:
设备
A
的额定电流
额定剖面
,
单位平方毫米
≤
0,2
PVC
扁形双芯软线
a
a.
这些电线只可以用在电线或者它的保护层进入
设备的
点和插头输入端之间他们的长度不超过
2
米时
。
在
> 0,2
和
≤
3
之
间
0,5
a
在
> 3
和
≤
6
之
间
0,75
在
> 6
和
≤
10
之
间
1,0 (0,75)
b
在
> 10
和
≤
16
之
间
1,5 (1,0)
b
在
> 16
和
≤
25
之
间
2,5
b.
拥有括号里边所标示出来的剖面的电线,当此
电线的
长度不超过两米时可以用在“移动设备”上。
在
> 25
和
≤
32
之
间
4
在
> 32
和
≤
40
之
间
6
在
> 40
和
≤
63
之
间
10
4.
管理
4.1
储存
所有水泵必须在干燥,无震动,无灰尘的室内使用,如可能,保持经常通风。
原包装在安装前一定保持完好。如无法保持包装完好,至少确保泵入口和出口封闭。
4.2
运输
避免产品受到不必要的摇晃和撞击。
产品的运输必须使用起重装备和标准托盘(如果可行)。
只有当部件可以被轻易吊起时才可以使用合适的麻绳或人造绳,如果可能,要与吊环螺栓连接。
如果是组装(装配)泵,用于吊起部件的吊环螺栓禁止吊组装后的电泵。
4.3
尺寸和重量
包装上的粘性标签包含泵的重量。
尺寸请见
92
页。
5.
警告
5.1
检查电机轴旋转方向
建议安装泵前检查转子能否正常运转。
将风扇罩
从电机后盖
凹槽处移开,旋开螺丝
和螺帽。用手转动风扇,
让转轴转动几分钟。如不能进行,拆开泵体,拧开螺丝
检查是否内部进入了杂物。按照
相反顺序重新组装。
禁止用钳子强行推动风扇或用其他工具试图松动水泵,这会导致水泵变
形或破损。
5.2
新系统
在运行新系统之前,一定要对阀门、管路、罐和连接部位进行彻底清洗。一定时期内,经常有电焊