ENGLISH 

 

22 

 

 

PUMP BLOCK function 

By simultaneously pressing and releasing the "+" and "-" buttons (fig 12, 1 - 2), the pump motor stops unconditionally and cannot start again 

until the "+" and "-" buttons (fig 12, 1 - 2) are pressed again simultaneously and released. This Inhibition also prevails over any motor start set in  

"MANUAL” mode. 

The blocking of the pump stops if DTRON3 and COM BOX are disconnected. Turning on the DTRON3 again or the absence of connection 

between DTRON3 and COM BOX does not affect the setting of the inhibition. 

 

ALARM RESET function 

The alarms can be set manually by pressing the ”Reset/Select” button (Figure 12, 3). 

 

9.3

 

SETUP mode 

Once in SETUP mode (see paragraph 8.1) 

With the exception of the CUT-IN function, the activation of each function causes the corresponding LED to light up, which will flash as 

described below:  

 

ON x 3 sec  

 

Flashing 0.3 sec ON and Off, 4 times 

SETTINGS SELECTION mode 

With the "Reset/Select" button (Figure 12, 3) you can go through the settings described below.  

The first setting you will find, once the SETUP Mode is activated, is the "CUT-IN Variation". 

 

CUT-IN Variation 

With this function it is possible to vary the pump CUT-IN value. This value can be increased/decreased with the "+" and "-" buttons (Fig 12, 1-2) 

and can assume the values represented in the barometric scale by flashing. 

Instead, the current value of the CUT-IN is highlighted with the corresponding LED lit with a steady light. 

 

 

Too low a CUT-IN value could prevent the pump turning on and keep it off at all times. 

Too high a CUT-IN value could cause a DRYRUN alarm. 

It is recommended not to exceed the CUT-IN value of: 

•  2.5 bar (36.2 psi) for models DTRON3 (X) 35/90 and 35/120  

•  3.5 bar (50.7 psi) for models DTRON3 (X) 45/120  

 

 

Enabling/disabling manual operation 

In this setting, the pump motor is switched on using the "+" button (Fig 12, 1). 

The "-" button (Fig 12, 2) restores normal operating conditions. 

 

Associating/Dissociating COM BOX / DTRON3 

In this setting, by pressing the "+" button (Fig 12, 1) for 5 seconds, the COM BOX temporarily enters the PLC association status through the 

power supply network. 

Pressing the "-" button (Fig 12, 2) for 5 seconds eliminates any association with the DTRON3. 

 

Enabling/disabling ANTICYCLING 

In this setting, use the "+" button (Fig 12, 1) to activate the ANTICYCLING function described above. 

The "-" button (Fig 12, 2) deactivates this function. 

 

10

 

 

COM BOX TROUBLESHOOTING 

FAULTS 

PROBABLE CAUSES 

REMEDIES 

The Pump and the COM BOX do 

not connect to each other 

1. They are galvanically separated 

1. Check that the two units are on the same power 

supply and in the same phase. 

2. They are too far apart 

2. Connect the two units at a shorter distance 

3. The two units are not associated 

3. Repeat the first association procedure described in 

8.3. 

 

Summary of Contents for DTRON3

Page 1: ...TRUCTIES VOOR INSTALLATIE EN ONDERHOUD NL INSTRUCCIONES DE INSTALACI N Y MANTENIMIENTO ES RU POKYNY K INSTALACI A DR B CZ ASENNUS JA HUOLTO OHJEET FI INSTALLATIONS OCH UNDERH LLSANVISNING SE INSTRUC I...

Page 2: ...SH page 12 FRAN AIS page 23 DEUTSCH seite 34 NEDERLANDS pag 45 ESPA OL p g 58 69 E TINA strana 81 SUOMI sivu 92 SVENSKA sid 103 ROM N pag 114 125 T RK E sf 137 POLSKI strona 148 MAGYAR oldal 159 PORTU...

Page 3: ...Fig Fig Image Abb Afb Fig Obr Kuva Fig Fig ekil Rys bra Fig Fig 1 Fig 2 Fig 3 Fig 5...

Page 4: ...Fig 6 Fig 7 Fig 8 Fig 9...

Page 5: ...Fig 10 Fig 11 Fig 12...

Page 6: ...danger for personal safety Notes and general information WARNINGS Read this documentation carefully before installation Installation and operation must comply with the local safety regulations in forc...

Page 7: ...he products that it may consider necessary or useful without affecting their essential characteristics who lack experience or knowledge on condition that they are under supervision or after they have...

Page 8: ...nly use the pump in clean water The pump must not be used to pump salt water sewage inflammable corrosive or explosive liquids e g petroleum petrol thinners greases oils The temperature of the liquid...

Page 9: ...r with I n 30 mA and that the earth system is efficient Any extension cables comply with the regulations in force 2 1 Mechanical Installation Install the pump in a location that is not exposed to free...

Page 10: ...ve protects the pump from breakage Installation in a well Install the pump so that the pump suction is at least 1 m 3 28ft above the bottom of the well to prevent the intake of sand and impurities Use...

Page 11: ...ressure above the CUT IN The pump stops even when there is no water safeguarding the motor see ANTI DRYRUN function Various alarms 4 2 Pump On OFF The pump motor is powered by the electronic control b...

Page 12: ...scribed here is also effective if starting is set to Manual mode 5 2 Auto mode In this mode the pump power supply is supplied to the motor according to the evolution of the user s requirements and the...

Page 13: ...e the plug out of the socket If the power cable or any electrical part of the pump is damaged the repair or replacement must be carried out by the manufacturer or by their technical assistance service...

Page 14: ...e in MONITOR mode pressure on the delivery of the DTRON3 pump 6 motor power status 4 DISABLE status of the pump XX current faults alarms 5 8 10 11 connection status of the COM BOX with the DTRON s 8 T...

Page 15: ...ons Figure 12 2 and Reset Select Figure 12 3 simultaneously for at least 3 seconds or wait for 1 minute without touching any button on the interface When switched on the COM BOX is in Monitor mode by...

Page 16: ...resented in the barometric scale by flashing Instead the current value of the CUT IN is highlighted with the corresponding LED lit with a steady light Too low a CUT IN value could prevent the pump tur...

Page 17: ...des personnes Notes et informations g n rales MISES EN GARDE Avant de proc der l installation lire attentivement cette documentation L installation et l utilisation doivent tre conformes aux r glemen...

Page 18: ...modifications qu il jugera n cessaires ou utiles sans en compromettre les caract ristiques essentielles ou mentales r duites ou avec un manque d exp rience et de connaissances condition qu elles soie...

Page 19: ...2 Liquides Pompables Utilisez la pompe uniquement dans de l eau propre La pompe ne doit pas tre utilis e pour pomper de l eau sal e des eaux us es des liquides inflammables corrosifs ou explosifs par...

Page 20: ...s endommag s Le raccordement lectrique doit tre effectu dans un endroit sec l abri de toute inondation L installation lectrique est quip e d un disjoncteur diff rentiel de da I n 30 mA et que le syst...

Page 21: ...cas des pompes DTRON3 Celui ci limite le nombre de red marrages de la pompe en compensant les petites fuites du syst me Le vase prot ge la pompe en cas de coups de b lier Le vase ne n cessite d aucune...

Page 22: ...s de d marrage sont remplies Cela se produit par exemple en ouvrant un robinet en r duisant la pression dans l installation La pompe s arr te nouveau lorsque la consommation d eau cesse c est dire lor...

Page 23: ...t la condition et active l alarme ANTICYCLING L alarme emp chera le moteur de la pompe de s allumer L alarme peut tre supprim e manuellement L alarme sera toujours supprim e automatiquement apr s 12 h...

Page 24: ...recommand une fois la pompe retir e du liquide de nettoyer les pi ces suivantes avec un simple jet d eau Filtre ouvert voir image 1A Filtre d aspiration avec flotteur en cas de version X voir image 3...

Page 25: ...ent de la pompe DTRON3 6 tat d alimentation du moteur 4 tat DISABLE d sactivation de la pompe XX anomalies alarmes en cours 5 8 10 11 tat de connexion de la COM BOX avec la les DTRON 8 En mode MONITOR...

Page 26: ...sser du mode SETUP au mode Monitor appuyez sur les touches Image 12 2 et Reset Select Image 12 3 simultan ment pendant au moins 3 secondes ou attendez 1 minute sans toucher aucune touche de l interfac...

Page 27: ...t peut prendre les valeurs repr sent es dans l chelle barom trique par clignotement La valeur actuelle du CUT IN est au contraire mise en vidence par l allumage fixe de la LED correspondante Une valeu...

Page 28: ...ium dwtgroup com Tel 32 2 4668353 DAB PUMPS IBERICA S L Calle Verano 18 20 22 28850 Torrej n de Ardoz Madrid Spain Info spain dwtgroup com Tel 34 91 6569545 Fax 34 91 6569676 DAB PUMPS INC 3226 Benchm...

Reviews: