background image

 

 
 
 
 
 
 
 
 
 

 

INSTALLATION/OPERATING INSTRUCTIONS 

 
 
 FOR 

 
 
 

 

AQUEFIER POOL HEATER 

Models WCC100B, WCC100C, WCC100L 

 
 
 
 
 
 

Trevor-Martin Corp., 4151 112

th

 Terrace North, Clearwater, FL 33762                                    Bulletin PH-100-0702

Summary of Contents for WCC100B

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS FOR AQUEFIER POOL HEATER Models WCC100B WCC100C WCC100L Trevor Martin Corp 4151 112th Terrace North Clearwater FL 33762 Bulletin PH 100 0702 ...

Page 2: ...ture and starts adding heat if required The AQUEFIER Pool Heater will keep your pool pump running until it reaches your chosen temperature even if the pool timer turns off CAUTIONS DISCLAIMERS The AQUEFIER Pool Heater operates in conjunction with your pool equipment Improper installation can cause damage to both your Pool Heater your pool pump and filter piping Only skilled technicians with approp...

Page 3: ...er temperatures to 100 degrees F c Before entering a pool or tub the user should measure the water temperature at several occupant locations using an accurate thermometer since the tolerance of the water temperature regulating devices may vary as much as or 5 degrees F d Alcohol drugs or medication should not be used before or during pool or tub use since their use may lead to unconsciousness with...

Page 4: ...by the normal operation of the heat pump 3 Do not install the Pool Heater in an enclosed area such as a filter equipment room It is important to prevent the cool discharge air from being drawn back into the heat pump A beach location presents additional concerns Exposure to salt water spray and high winds will cause premature wear on the heat pump Salt and sand accumulation will clog up the heat p...

Page 5: ...n Heat Pump instructions enclosed Bonding to Pool Steel Electrical corrosion known as electrolysis will occur if the heater is not bonded to the pool reinforcement steel Most local codes also require that the water pump be bonded Connect using a 8 gauge or larger solid copper wire to bond the cabinet to the pool reinforcement steel Power to the Pool Pump A standard feature on the Aquifier Pool Hea...

Page 6: ...rect Replace the front panel on the cabinet POOL PIPING CONNECTIONS The Pool Heater is designed to handle the full flow from the pool pump No bypass is required if the water flow is in the 20 to 80 gallon per minute range The Pool Heater piping must be connected at a point in the pool piping loop after the pool water passes through the filter and before the chlorinator or chemical feeder Connectin...

Page 7: ...b clockwise or counter clockwise or remove the clear plastic weather cover insert the 1 8 th inch hex wrench provided through the opening in the face of the digital temperature control and adjust the set point up or down as desired For more detailed instructions on the digital temperature refer to the Goldline SP 33 instructions enclosed After adjusting the temperature control check the water temp...

Page 8: ...owed to start for an additional 4 minutes In most cases the heater will not start until at least 8 minutes has passed without resetting the on off switch or the breakers The heater will continue to heat the pool until the temperature setpoint has been satisfied PLEASE NOTE 1 It is important to remember that the pool heater will not run unless the pool pump is running 2 Water vapor will condense on...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ...er Side Pressure Drop Water Flow gal min Pressure Drop psig 20 0 23 30 0 46 40 0 74 50 1 06 60 1 42 70 1 86 80 2 32 Temperature Rise Across Heater Water Flow gal min Temperature Rise deg F 20 10 0 30 6 7 40 5 0 50 4 0 60 3 3 70 2 8 80 2 5 ...

Page 14: ...s that are installed Check filtering system Check pump and impeller Check that pressure switch is closed needs 2 psi to close Wait at least 8 min without resetting on off switch or breakers Set temperature setpoint above water temperature Goldline control terminals C and NO close on call for heat Pool water does not reach temperature setpoint Heater runs only when pool timer is on Outside air temp...

Page 15: ... any other liability in connection with this product except as may be authorized by an officer of Trevor Martin Corporation in a signed written document THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT APPLY TO THIS SALE LIMITATION OF REMEDY Trevor Martin Corporation will replace or repair at its option any product or component found to be defective durin...

Page 16: ......

Reviews: