EE Pro for TI-89, 92 Plus
Analysis - Polyphase Circuits
18
VCA_:
(Voltage in V across lines C and A)
A real or complex number, or algebraic exp.
IA_
:
(Line Current A in A)
A real or complex number, or algebraic exp.
IB_
:
(Line Current B in A)
A real or complex number, or algebraic exp.
IC_
:
(Line Current C in A)
A real or complex number, or algebraic exp.
P
:
(Phase Power in W)
A real number or algebraic expression.
WAB
:
(Wattmeter reading in across lines A and B)
A real number or algebraic expression.
WAC
:
(Wattmeter reading in W across lines A and C)
A real number or algebraic expression.
Example 4.3 -
A Delta network consists of three impedances of 50 - 25*i with a line voltage of 110 volts across
line A and B. Find the line current and power measured in a two-wattmeter measurement system.
Input Parameters
Calculated Output
1. Select
Balanced
Delta Load.
2. Enter the values 50 - 25*i for
ZZ_
and 110_V
for VAB_.
3. Press
„
to calculate performance characteristics of the circuit.
Z
Z
Z
V
AB
W
AC
W
AB
V
CA
V
BC
I
A
I
C
I
B
A
C
B
.
Fig. 4.4 Wattmeter Measurement in a Delta Circuit
The results of computation are listed below:
VBC_: -55 - 95.2628*
i
VCA_: -55 + 95.2628*
i
IA_: 3.4021 - .204205*
i
IB_: -1.8779 – 2.8442*
i
IC_: -1.5242 + 3.04841*
i
P:
193.6
WAB: 206.569
WAC: 374.231