A synchron-group (ZA-BSY+) can be count up to 8
drives, which communicate by a bus. Each drive has
it’s own adress. This adress is configurable with SW-
BSY+.
The last drive of a synchron-group is the master,
which controls the other drives, the slaves. Different
forces between the drives of a group will balanced
with intelligent force- and position control. In case of
malfunction respective cutoff of a drive, all drives will
shut down from the master-drive.
Functional description
99.824.31 1.2/03/12
ZA-BSY+
9/20
English
Maintenance and cleaning
Inspection and maintenance has to be carried out
according to D+H maintenance notes. Only original
D+H spare parts may be used. Repair is to be carried
out exclusively by D+H.
Wipe away debris or contamination with a dry, soft
cloth.
Do not use cleaning agents or solvents.
Declaration of Conformity
Electrical devices, accessories and packaging
should be sorted for environmental-friendly recycling.
Do not dispose electrical
devices into household waste!
Only for EC countries:
According the European Guideline
2002/96/EC for waste electrical and
electronic equipment and its implemen-
tation into national right, electrcal devices that are no
longer usable must be collected separately and
disposed of in an environmentally correct manner.
Disposal
Guarantee
You will get
for all D+H products
from date of verified handing over of the system up to
maximal 3 years after date of delivery, when
mounting and starting has been carried out by
D+H guarantee is expired, with connection of D+H
components with external systems or with mixing of
D+H products with parts of other manufacturers.
2 years guarantee
an
authorized D+H-distributor.
Visual inspection:
Wiring:
Null balance:
Call D+H Service:
Only one master-drive allowed.
The master has, according to common drives,
the last adress.
The adress is sticked on the drive. Slaves are
nubered downwards.
Example: In a group, composed of 3 drives,
there is a master 3, a slave 2 and a slave 1drive.
Attention: only applies by factory set. as soon as
the drives were reprogramized with SW-BSY+
he factory set adressing does not apply any
longer.
Is the group wired correctly?
Therefore look connection diagrams.
It should be null balanced.
Software SW-BSY+ or the special magnet
MAG 502 is required.
Drives must be configured.
Software SW-BSY+ is required.
Trouble shooting
We declare under our sole responsibility that the
product described under “Technical Data” is in
conformity with the following directives:
2004/108/EC, 2006/95/EC
Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek
Thomas Kern
Maik Schmees
Member of the Board
Authorized signatory, Technical Director
12.10.2010