English
English
ZA-K-BSY+
ZA-K-BSY+
99.823.99 1.8/05/19
99.823.99 1.8/05/19
8/20
9/20
Pin Assignment
Connection: Page 18 - 19
* if power is set on L-CLOSE
and L-OPEN simultaneously,
the drive opens in HS
Visual inspection:
Only one master-drive allowed.
The master has, according to common drives,
the last adress.
The adress is sticked on the drive. Slaves are
nubered downwards.
Example: In a group, composed of 3 drives,
there is a master 3, a slave 2 and a slave 1drive.
Attention: only applies by factory set. as soon as
the drives were reprogramized with SCS
he factory set adressing does not apply any
longer.
Wiring:
Is the group wired correctly? Please refer to the
connection diagrams in this regard
Adjustment of zero point:
Adjust the zero point.
Software SCS with BI-BT2 or the
special magnet MAG 502 is required
Call D+H Service:
Drives must be configured.
Software SCS and BI-BT2 incl. connection
cable (30.006.23) is required
Troubleshooting
YE/GN (PE)
second connecting cable
(standard 2,5 m)
second connecting cable
(standard 2,5 m)
A synchronous group ZA-K-BSY+ (-HS) can contain
up to 4 drives, which communicate via bus. Each
drive has its own address, configurable with SCS
and BI-BT2. The last drive of a synchronous group is
the master, which controls the other drives, the
slaves. Differences in forces between the drives of a
group are balanced by means of intelligent force and
position control. In the event that a drive
malfunctions, all the drives are automatically cut off.
Functional description
Option -SZ-SA
GN (Data B)
YE (Data A)
BN (L - CLOSE)*
BK (L - OPEN)*
BU (N)
230 V
AC
Option -SGI
GN (Data B)
YE (Data A)
BN (L - CLOSE)*
BK (L - OPEN)*
BU (N)
230 V
AC
230 V
AC
Standard
GN (Data B)
YE (Data A)
BN (L - CLOSE)*
BK (L - OPEN)*
BU (N)
Mounting examples
triangular pyramid *
domelight
pyramid *
weighty wing
Uncritical load distribution
Critical load distribution
* Guiding device required by customer in case of complete lift-off of pyramid/domelight,
because of possible lateral load due to wind pressure!
max. 160 V / 1 A
Electrical devices, accessories, batteries and packa-
ging should be sorted for environmental-friendly
recycling. Do not dispose electrical devices and
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for
waste electrical and electronic equipment and its
implementation into national right, electrcal devices
that are no longer usable must be collected separa-
tely and disposed of in an environmentally correct
manner.
Disposal
Declaration of Conformity
We declare under our sole responsibility that the
product described under “Technical Data” is in
conformity with the following directives:
2014/30/EU, 2014/35/EU
Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder
Maik Schmees
Member of the Board
Authorized signatory, Technical Director
17.11.2015
Maintenance and cleaning
Inspection and maintenance has to be carried out
according to D+H maintenance notes. Only original
D+H spare parts may be used. Repair is to be carried
out exclusively by D+H.
Wipe away debris or contamination with a dry, soft
cloth.
Do not use cleaning agents or solvents.
Guarantee
You will get 2 years guarantee for all D+H products
from date of verified handing over of the system up to
maximal 3 years after date of delivery, when
mounting and starting has been carried out by an
authorized D+H-distributor.
D+H guarantee is expired, with connection of D+H
components with external systems or with mixing of
D+H products with parts of other manufacturers.
WH (n.c.)
BN (n.c.)
YE (+SGI)
GN (-SGI)
GN (SZ)
BN (SZ)
YE (SA)
WH (SA)