87
UART Commands
Command
Description & Parameters
UART M BaudRate=XXX
Set the RS-232 baud rate for the specified HDBaseT output.
M
= A ~ H
Available values for
XXX
:
2400 4800 7200 9600
14400 19200 38400 57600
115200
UART M DataBit=XXX
Set the RS-232 data bits for the specified HDBaseT output.
M
= A ~ H
XXX
= 5 ~ 8
UART M Parity=XXX
Set the RS-232 parity for the specified HDBaseT output.
M
= A ~ H
Available values for
XXX
:
None Odd Even
UART M UartSend={DataString}
Transmit a data string to the RS-232 port on the specified HDBaseT
output.
M
= A ~ H
UART M Status
Display the current RS-232 settings for the specified HDBaseT
output.
M
= A ~ H
Note: Commands will not be executed unless followed by a carriage return.
Commands are not case-sensitive.