![background image](http://html1.mh-extra.com/html/cyp/cplus-v2pel/cplus-v2pel_operation-manual_2705231024.webp)
19
COMMAND
Description and Parameters
SET USER 1 EDID DATA N1
Upload a new User EDID in HEX format.
N1
= {EDID data in hh,hh,hh,hh,... HEX pair format}
GET USER 1 EDID DATA
Show the Current User EDID as HEX data.
GET SINK N1 EDID DATA
Show the EDID from Output
N1
as HEX data.
N1
= A ~ B
[Output port]
GET IN 1 EDID DATA
Show the EDID currently used by the input as HEX data.
GET INTERNAL N1 EDID DATA
Show Internal EDID
N1
as HEX data.
N1
= 1 ~ 6
[Internal EDID number]
SET IN 1 HDCP MODE N1
Set the unit’s HDCP behavior.
Available values for
N1
:
0
[Disable HDCP]
1
[Follow source]
2
[Follow display]
GET IN 1 HDCP MODE
Show the unit’s current HDCP behavior setting.
GET IN 1 HDCP STATUS
Show the current status of HDCP on the Input.
Available responses:
0
[No HDCP]
1
[HDCP 1.x]
2
[HDCP 2.2]
Summary of Contents for CPLUS-V2PEL