COMMAND
Description and Parameters
GET UART 1 DATA BIT
Show the current RS-232 data bits.
SET UART 1 PARITY N1
Set the RS-232 parity value.
Available values for
N1
:
0 [None]
1 [Odd]
2 [Even]
GET UART 1 PARITY
Show the current RS-232 parity value.
SET IN 1 NAME N1
Set the text name for the Input.
N1
= {Name string}
[Input name]
GET IN 1 NAME
Show the Input’s current text name.
SET OUT N1 NAME N2
Set the text name for Output
N1
.
N1
= A ~ B
[Output port]
N2
= {Name string}
[Output name]
GET OUT N1 NAME
Show the current text name for Output
N1
.
N1
= A ~ B
[Output port]
GET IN NAME LIST
Show all Input text names.
GET OUT NAME LIST
Show all Output text names.