![background image](http://html1.mh-extra.com/html/cyp/cplus-v2pel/cplus-v2pel_operation-manual_2705231027.webp)
22
COMMAND
Description and Parameters
GET AUTOMATION EVENT N1 UART A COMMAND
Show the currently defined RS-232 command to send when
automation event
N1
is triggered.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
SET AUTOMATION EVENT N1 UART A DELAY N2 SEC
Set the delay (in seconds) to wait before triggering RS-232
automation event
N1
.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
N2
= 0 ~ 240
[Delay in seconds]
GET AUTOMATION EVENT N1 UART A DELAY
Show the currently set delay (in seconds) to wait before triggering
RS-232 automation event
N1
.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
Summary of Contents for CPLUS-V2PEL
Page 2: ......