COMMAND
Description and Parameters
SET AUTOMATION EVENT N1 UART A N2
Enable or disable RS-232 automation event type
N1
.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
N2
= ON, OFF
[Enable/Disable event type]
GET AUTOMATION EVENT N1 UART A
Show the current state of RS-232 automation event type
N1
.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
SET AUTOMATION EVENT N1 UART A COMMAND N2
Set the RS-232 command to send when automation event
N1
is
triggered.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
N2
= {Command}
[Command to send]