4. Control System Commands
COMMAND
DESCRIPTION AND PARAMETERS
GET EVENT N1 CONDITION
Show Event N1’s activation condition
(conditions displayed depend on the
Event type).
N1 = 1 ~ 64
[Event number]
SET EVENT N1 MODE N2
Set Event N1 to use activation mode
N2.
N1 = 1 ~ 64
[Event number]
Available values for N2:
1
[Once]
2
[Single Mode]
3
[Repeat Mode]
4
[Toggle Mode]
GET EVENT N1 MODE
Show Event N1’s activation mode.
N1 = 1 ~ 64
[Event number]
SET EVENT N1 MACRO N2
Assign macro N2 to Event N1.
N1 = 1 ~ 64
[Event number]
N2 = 1 ~ 64
[Macro number]
GET EVENT N1 MACRO
Show the macro currently assigned
to Event N1.
N1 = 1 ~ 64
[Event number]
SET EVENT N1 TOGGLE MACRO N2
Assign the secondary macro to use
when Event N1 is set to toggle mode.
N1 = 1 ~ 64
[Event number]
N2 = 1 ~ 64
[Macro number]
GET EVENT N1 TOGGLE MACRO
Show Event N1’s secondary macro
when in toggle mode.
N1 = 1 ~ 64
[Event number]
SET EVENT N1 TIMER N2
Set Event N1’s hold timer duration to
N2 seconds.
N1 = 1 ~ 64
[Event number]
N2 = 0 ~ 65535 [Seconds]
Note: Not used in all Event modes.