AutoView Commander Installer/User Guide
Symptom
Action
OSD menu does not “pop-up”
Verify that you are pressing the Control key twice
within one second. If the problem persists, contact
Cybex Technical Support.
Unable to change channels
Verify that the channel is powered. Check the
using OSD
address configured in OSD. If the computer is
powered and the address is correct, call Cybex
Technical Support.
Administrator password is
Call Technical Support.
forgotten
User password is forgotten
Contact your system administrator.
General Keyboard/Video
If the building has 3-phase AC power, ensure
Problems
that the computer, the AutoView and the
monitor are on the same phase. Best results are
obtained when they are on the same circuit.
Use only Cybex supplied cable. Cybex warranties do
not apply to damage resulting from user supplied
cable.
Do not use a 2-wire extension cord in any Cybex
product configuration.
Test AC sockets at computer, AutoView and
monitor for proper polarity and grounding.
Use only with grounded sockets at the computer,
AutoView and monitor. When using a backup
power supply (UPS), power the computer, AutoView
and the monitor off the supply.
System lockup during
If there is no keyboard, mouse or push-button
paired operation
channel selection function, try to bring up the
OSD menu. If it activates, reselect your channel
and verify that the channel functions normally. If
the problem persists, contact Technical Support.
If the OSD menu does not activate, verify that the
serial cable and video cables are securely attached
to both boxes. If not, reattach and try the OSD
menu again. If the problem persists, contact
Technical Support.