Parameter
Name
Description
Setting Range
Holding Stop
Width
Speed Holding function will stop.
Min.: 0 pulse
Max.: 4096 pulse
b9-02 Zero Speed
Holding On/ Off
0 :Zero Speed Holding Disabled.
Controller coasts to stop when the frequency is
zero.
1 : Zero Speed Holding Enabled.
Zero Speed Holding starts when the frequency is
zero. The holding current is set in b2-01 and it will
be limited to below 20% of the controller rated
current.
Default
∶
0
Min.: 0
Max.: 1
b9-03 Zero Speed
Holding Time
Sets the Zero Speed Holding time. Controller
will coast to stop when the Zero Speed Holding
time is longer than this setting. Set 00.00 to
disable Zero Speed Holding or set 99.99 to
enable this function continuesely .
Default
∶
0.10sec
Min.: 00.00sec
Max.: 99.99sec
b9-04
Position Control
Input Command
Direction
0 : Forward
1 : Reverse
Default
∶
0
Min.: 0
Max.: 1
Group C, Tuning
C1: Acc./Dec. Time
C1-00
<4>
Acceleration Time
1
Sets the time that the controller accelerates
from 0Hz to the maximum output.
Default
∶
10.0 s
Min.: 0.0 s
Max.: 6000.0 s
C1-01
<4>
Deceleration Time
1
Sets the time that the controller decelerates
from the maximum output to 0Hz.
C1-02
<4>
Acceleration Time
2
Sets the time that the controller accelerates
from 0Hz to the maximum output.
C1-03
<4>
Deceleration Time
2
Sets the time that the controller decelerates
from the maximum output to 0Hz.
C1-04
<4>
Acceleration Time
3
Sets the time that the controller accelerates
from 0Hz to the maximum output.
C1-05
<4>
Deceleration Time
3
Sets the time that the controller decelerates
from the maximum output to 0Hz.
C1-06
<4>
Acceleration Time
4
Sets the time that the controller accelerates
from 0Hz to the maximum output.
C1-07
<4>
Deceleration Time
4
Sets the time that the controller decelerates
from the maximum output to 0Hz.
C1-08 Fast Stop Time
Sets the time to stop the controller faster.
Summary of Contents for CPSPI3700EVF380
Page 7: ...6 WarningLabel ...
Page 31: ...30 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON ...
Page 94: ......