Parameter
Name
Description
Setting Range
55 (Offset Frequency 1 to 3).
Group d, Load Parameters
d1: V/F Characteristics
d1-00 Input Voltage
Setting
Sets the input voltage of the controller.
Always set the input voltage of the controller to
this parameter.
Default: Determined
by A1-03
Min.: 155 V
Max.: 255V <3>
d1-01 V/F Pattern
Selection
0
∶
50 Hz (Constant Torque Characteristic 1)
1
∶
60 Hz (Constant Torque Characteristic 2)
2
∶
60 Hz (Constant Torque Characteristic 3), 50
Hz base
3
∶
72 Hz (Constant Torque Characteristic 4), 60
Hz base
4
∶
50 Hz (Derated Torque Characteristic 1)
5
∶
50 Hz (Derated Torque Characteristic 2)
6
∶
60 Hz (Derated Torque Characteristic 3)
7
∶
60 Hz (Derated Torque Characteristic 4)
8
∶
50 Hz (High Starting Torque Characteristic 1)
9
∶
50 Hz (High Starting Torque Characteristic 2)
A
∶
60 Hz(High Starting Torque Characteristic 3)
B
∶
60 Hz(High Starting Torque Characteristic 4)
C
∶
90 Hz, 60 Hz base
D
∶
120 Hz, 60 Hz base
E
∶
180 Hz, 60 Hz base
F
∶
60Hz (Constant Torque Characteristic)
(Default)
Default: F
Range: 0 to 9; A to F
d1-02 Maximum Output
Frequency
When d1-01 ≦ E, parameters d1-02 to d1-11
can be used to monitor the V/F pattern.
When d1-01 = F, parameters d1-02 to d1-11
can be used to create a V/F pattern.
Default: <1>
Min.: 25.0 Hz
Max.: 400.0 Hz
d1-03 Maximum Voltage
Default: <1>
Min.: 0.0 V
Max.: 255.0 V <3>
d1-04 Base Frequency
Default: <1>
Min.: 0.0 Hz
Max.: Defined by
d1-02
d1-05 Base Voltage
Default: <1>
Min.: 0.0 V
Max.: 255.0 V <3>