Parameter
Name
Description
Setting Range
d3-03 Number of PM
Poles
Sets the number of poles.
Default: Determined
by o2-03
Min.: 2
Max.: 48
d3-04 PM Rotor
Resistance (r 1)
Sets the resistance per phase in units of 0.001
Ω. Refrain from change once this parameter is
set.
Default: Determined
by o2-03
Min.: 0.000 Ω
Max.: 65.000 Ω
d3-05 PM d-Axis
Inductance (Ld)
Sets the d-axis inductance in units of 0.01 mH.
Refrain from change once this parameter is set.
Default: Determined
by o2-03
Min.: 0.00 mH
Max.: 600.00 mH
d3-06 PM q-Axis
Inductance (Lq)
Sets the q-axis inductance in units of 0.01mH.
Refrain from change once this parameter is set.
Default: Determined
by o2-03
Min.: 0.00 mH
Max.: 600.00 mH
d3-07
PM Induction
Voltage Constant 1
(Ke)
Sets the induced peak voltage per phase in
units of 0.1 mV/(rad/s) (electrical angle). Set this
parameter when driving an IPM (SSR1 or SST4
series).
Set 0 to d3-09 before setting.
Default: Determined
by o2-03
Min.: 0.0 mV/(rad/s)
Max.: 2000.0
mV/(rad/s)
d3-09
PM Induction
Voltage Constant 2
(Ke)
Sets the induced line-to-line voltage in units of
0.1 mV/ (r/min) (mechanical angle). Set this
parameter when driving an SPM.
Set 0 to d3-07 before setting.
Default: Determined
by o2-03
Min.: 0.0 mV/
(r/min)
Max.: 2000.0 mV/
(r/min)
d3-10
<7>
PM Load Rated
Voltage
Sets the PM Load Rated voltage according to
the nameplate.
Default: 200.0 V
Min.: 0.0 V
Max.: 255.0 V <3>
d3-11
<7>
PM Base
Frequency
Sets the PM base frequency according to the
nameplate.
Default: 87.5 Hz
Min.: 0.0 Hz
Max.: 400.0 Hz
d3-12
<7> PM Base Speed
Sets the PM base speed according to the
nameplate.
Default
∶
1750 rpm
Min.: 0 rpm
Max.: 24000 rpm
Group E, Multi-Function Terminals
E1: Multi-Function Digital Inputs
Summary of Contents for CPSPI3700EVF380