Using the 3ware Disk Manager®
Cybernetics
UM-MV-86-B1-0801
E-mail Notification
Use the fields in this section to set up and manage notifications of events by e-mail.
•
Send E-mail
: This field determines whether e-mail notification is Enabled or Disabled.
•
Send Severity and Above
: Specifies the type of events for which notifications should
be sent. A severity of Information will send e-mails for all alarms, a severity of
Warning will send e-mail for alarms with severity of Warning and Error. A severity of
Error will send e-mail for alarms with severity of Error.
•
Sender
: Enter the email address which will appear in the “From” field.
•
Recipient
: The e-mail address to which notifications should be sent. You can enter
multiple addresses, separated by commas (,).
•
Server (name or IP)
: If the machine on which you are running 3DM has access to a
nameserver, you may enter the machine name of the mail server in the Server field.
Otherwise, use the IP address.
•
Save E-mail Settings button
: Saves the e-mail notification settings.
•
Send Test Message button
: Sends a test message using the saved e-mail settings.
Password
Use the fields in this section to set the passwords for the User and Administrator. When
3DM is first installed, the default password for both is 3ware.
Change Password For
: Select the access level for which you are setting the password:
User or Administrator. Users can only view status information in 3DM, while Administra-
tors can make changes and administer the controller and associated drives.
Current Password
: Enter the current password.
New Password
: Enter the new password.
Confirm New Password
: Enter the new password a second time, to be sure you have
entered it correctly.
Change Password button
: Saves password changes.
Page Refresh
Minutes Between Refresh
: Displays how frequently pages in 3DM will be refreshed with
new data from the controller. To change this setting, select another option from the drop-
down. If you prefer 3DM to only refresh when you click Refresh Page, select Never.
The Login, Help and Drive SMART data pages do not automatically refresh. All other
3DM pages do.
Summary of Contents for miSAN-V6
Page 104: ...104 Operating the Web Control Panel Cybernetics UM MV 86 B1 0801 ...
Page 110: ...110 Telnet Menu System Cybernetics UM MV 86 B1 0801 ...
Page 146: ...146 Packing and Shipping Instructions Cybernetics UM MV 86 B1 0801 ...
Page 174: ...174 Cybernetics UM MV 86 B1 0801 ...
Page 182: ...182 Cybernetics UM MV 86 B1 0801 ...
Page 184: ...184 Cybernetics UM MV 86 B1 0801 ...