GENERAL INSTALLATION & SERVICE WARNINGS
The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments . There is a small amount
of “give” to properly connect the piping, but the water filter is not designed to support the weight of the plumbing .
Do not use Vaseline
®
, oils, other hydrocarbon lubricants or spray silicone anywhere . A silicone lubricant may be used on black
“O” Rings, but is not necessary .
Avoid any type of lubricants, including silicone, on red or clear lip seals.
Do not use pipe dope or other sealants on threads.
Teflon
®
tape must be used on the threads of the 1” NPT inlet and outlet, the
brine line connection at the control valve, and on the threads for the drain line connection . Teflon
®
tape is not used on the nut
connections or caps because “O” Ring seals are used . The nuts and caps are designed to be unscrewed or tightened by hand or
with the special plastic Service Wrench, #CV3193-02 . If necessary pliers can be used to unscrew the nut or cap . Do not use a
pipe wrench to tighten nuts or caps .
Do not place screwdriver in slots on caps and/or tap with a hammer.
SITE REQUIREMENTS
• water pressure – 25-100 psi
• current draw is 0 .5 amperes
• water temperature – 33-100°F (0 .5-37 .7°C)
• the plug-in transformer is for dry locations only
• electrical – 115/120V, 60Hz uninterrupted outlet
• the tank should be on a firm level surface
1. STANDARD INSTALLATION CONFIGURATION:
There are four different types of regeneration configurations detailed in
this manual: Standard, Clean Water Regeneration, AutoFlush, and Clean Water Regeneration with AutoFlush . The following
illustrations display a standard installation while the following pages display additional installation configurations .
WELL WATER INSTALLATION
MUNICIPAL INSTALLATION