![CUSTOM CARE CCUF-844 Installation Instructions & Owner'S Manual Download Page 28](http://html1.mh-extra.com/html/custom-care/ccuf-844/ccuf-844_installation-instructions-and-owners-manual_2700757028.webp)
28
UF SERIES SPECIFICATIONS:
1
Flow rates depend upon pressure, temperature, and
suspended solids being removed.
*Molecular weights of tannins vary greatly. It is important that
the filtration level be demonstrated prior to installation.
NOTE:
This product is not certified as a microbiological purifier
and should not be applied as a stand-alone disinfection solution
for microbiologically unsafe water.
Operating Specifications
Application Specifications
Filtration Level (micron) . . . . . . . . . . . . . . 0 .02
1Peak Flow Rate (at 77º F and 60 psi) . . . 12 gpm
Continuous Flow Rate . . . . . . . . . . . . . 10 gpm
Water Pressure Range (psi) . . . . . . . . . . 10-100
Water Temperature . . . . . . . . . . . . . . 35-100º F
Electrical Requirements (V/Hz) . . . . . .100V/60Hz
Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1"
Total Dimensions (inches):
Media Tank . . . . . . . . . . . . . . . . . . . . . 8"x44"
Pre-filtration (micron) . . . . . . . . . . . . . . . . . . 5
Chlorine (ppm, continuous flow) . . . . . . . . . . 1
Iron, ppm . . . . . . . . . . . . . . . . . . . . . . . . <0 .3
Manganese, ppm . . . . . . . . . . . . . . . . . . 0 .05
pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Tannin . . . . . . . . . . . . . . . . . . . . . . .Variable*