PROGRAMMING PROCEDURES
1. Set time of day:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset .
STEP 1
– Press
SET
CLOCK
.
STEP 2
–
CURRENT TIME (HOUR):
Set the hour of the day using
+
or
—
buttons . AM/PM toggles after 12 .
Press
NEXT
to go to step 3 .
STEP 3
–
CURRENT TIME (MINUTES):
Set the minutes using
+
or
—
buttons . If it is desired to back up to the
previous step press
REGEN
button once . Press
NEXT
to go to step 4 .
STEP 4
–
CURRENT DAY:
Set the day of the week using
+
or
—
buttons . Pressing
NEXT
will exit
SET
CLOCK
and
return to the general operating display .
1
TIME
HOUR
AM
SET
2:00
TIME
MINUTES
AM
SET
2:00
2
3
CURRENT DAY
SET
MON
4
Return to general display.
2. Programming:
NOTE:
The manufacturer has preset the control valve to back flush once a day, with a 300
Gallon Setting between regenerations . If 300 gallons are used the unit will regenerate at the next
regeneration time .
STEP 1
– Press
NEXT
and
+
simultaneously for 3 seconds .
STEP 2
– Set the time between regenerations . The manufacturer has set this for once per day . To
change use the
+
or
—
buttons, toggle the correct amount of regenerations per day or
select “OFF” and press
NEXT
to advance to days between regeneration . If a specific
number of days between regeneration is desired press the
+
or
—
buttons to toggle to
the correct number . From the day screen, to return back to multiple regenerations in one
day press both the
CLOCK
and
+
button at the same time .
STEP 3
–
REGENERATION HOUR:
The manufacturer has factory set 12:00 A .M . as the default .
This is the hour of day for regeneration and can be reset by using
+
or
—
buttons .
“AM/PM” toggles after 12 . The default time is 12:00 a .m . (recommended for a normal
household) .
STEP 4
–
REGENERATION MINUTES:
Set the minutes using
+
or
—
buttons . Press
NEXT
to go
to step 6 . Press
REGEN
to return to previous step . To initiate an immediate manual
regeneration, press and hold the
REGEN
button for three seconds . The system will begin
to regenerate immediately . The control may
be manually stepped through the regeneration cycles by pressing
REGEN
.
STEP 5
–
SERVICE ALARM GALLONS:
The manufacturer has factory set “OFF” as the default .
This feature is used to signal service into the future . This is typically set by the installing
dealer to warn homeowner that service is required after a preset number of gallons have
been consumed . If the feature is active, a specific gallon amount will appear .
STEP 6
–
SERVICE ALARM TIME:
The manufacturer has factory set “OFF” as the default . This
feature is used to signal service into the future . This is typically set by the installing dealer
to warn homeowner that service is required after a period of time has passed . If the
feature is active, a specific number of days will appear .
1
2
REGEN TIME HOUR
AM
SET
2:00
3
REGEN TIME MINUTES
AM
SET
2:00
4
LIGHT NORMALLY
SET
ON
8
Return to general display.
5
6
7
REGENS PER DAY
SET
4 PER
SERVICE ALARM
SET
OFF
SERVICE ALARM
SET
OFF
YR
GAL
ALARM BUZZER START
SET
ALARM BUZZER END
SET
6:00
AM
10:00
PM
ALARM BUZZER
SET
ON
Continue to next page