![CUSTOM CARE CCUF-844 Installation Instructions & Owner'S Manual Download Page 32](http://html1.mh-extra.com/html/custom-care/ccuf-844/ccuf-844_installation-instructions-and-owners-manual_2700757032.webp)
32
MANUAL REGENERATION
NOTE:
For UF filters with optional
chlorine generator, if brine tank does
not contain salt, fill with salt and wait
at least two hours before regeneration .
If you need to initiate a manual
regeneration, either immediately, or the
same night at the preprogrammed time
for regeneration (typically 2:00 AM),
complete the following steps .
For Immediate Regeneration:
Press and hold
REGEN
until valve motor
starts (typically 3 seconds) .
For Regeneration the same night:
Press and release
REGEN
(notice that flashing “REGEN TODAY” appears) .
ERROR
If the display toggles between “Error”
and an error code (i .e . a number), call
a service technician and report the
error code .
BYPASS VALVE OPERATION
To shut off water to the system, position arrow handles as shown in
the bypass operation diagram below . If your valve doesn’t look like
the diagram below, contact your service technician for instructions
on how to shut off water .
REGEN TODAY
MON
GPM
2:40
8
PM
REGEN TODAY
and
TIME OF DAY
will flash alternately if a regeneration
is expected tonight.
NORMAL OPERATION
BYPASS OPERATION
ERROR
106
CALL FOR SERVICE
QUICK REFERENCE GUIDE:
GENERAL OPERATION
When the system is operating,
one of six displays will be shown:
1 . time of day/gpm
2 . flow rate
3 . vacation mode
4 . capacity remaining
5 . days to a regen
6 . dealer name and phone
number
Pressing
NEXT
will toggle
between the six choices .
TO SET TIME OF DAY
In the event of a prolonged power outage, time of day flashes,
indicating that this needs to be reset . All other information will be
stored in memory no matter how long the power outage .
1 . Accessed by pressing
SET
CLOCK
2 . Adjust hours with
+
and
—
buttons, AM/PM toggles at 12
3 . Press
NEXT
4 . Adjust minutes with
+
and
—
buttons
5 . Press
NEXT
6 . Adjust current day with
+
and
—
buttons
7 . Press
NEXT
to complete and return to normal operation
ON VACATION
NO
DAYS TO A REGEN
GPM
1
8
CAPACITY REMAINING
GPM
GAL
300
8
FLOW RATE
GPM
8.0
TIME OF DAY
MON
GPM
2:40
8
PM
PHONE NUMBER
DEALER NA
CURRENT DAY
SET
MON
TIME
MINUTES
SET
TIME
HOUR
SET
2:00
AM
6:35