15
OPERATING DISPLAYS AND MAINTENANCE
OPERATING DISPLAYS AND MAINTENANCE
3 .
REGENERATION MODE:
Standard UF Filters are set to regenerate once a day .
This is a short (2 minute) back flush of the membrane . If water is used at this time,
it may be possible to notice untreated water in the system . If this becomes an issue
please contact dealer as options are available to alleviate this . When the system
begins to regenerate, the display will include information about the step of the
regeneration process and the time remaining for that step to be completed . The
system runs through the steps automatically and will reset itself to provide treated
water when the regeneration has been completed .
4 .
MANUAL REGENERATION:
Sometimes there is a need to regenerate before
the control valve calls for it . This may be needed if a period of heavy water use is
anticipated or if a pressure drop is noticed in the system .
• To initiate a manual regeneration
at the next preset regeneration time,
press and release
REGEN
. The words “REGEN TODAY” will flash on the display
to indicate that the system will regenerate at the next regeneration time (set in
Programming) .
If you pressed the
REGEN
button
in error, pressing the button again will cancel the command.
• To initiate a manual regeneration
immediately,
press and hold the
REGEN
button for three seconds . The system will begin to regenerate immediately .
This command cannot be cancelled.
On Standard UF Filters
once a manual regeneration is initiated, the unit will proceed to the backwash position . In this
position a two minute flush to the drain will occur . This backwash allows for flushing of particulates from the membrane to the
drain . Once this is complete, the unit transfers to a one minute rinse . This rinses the tank of these same particles .
5 .
POWER LOSS AND BATTERY REPLACEMENT:
If an extended power outage
occurs, the control valve will retain the time of day settings until the board's battery is
depleted . Once the battery is depleted, the display will appear dark and absent of any
information . If this occurs, following these steps will determine if the problem is a low
battery or a board failure .
To determine if the battery is depleted:
1 . Remove valve cover . Disconnect power from PC Board at the four pin connector at
the bottom of the board .
2 . Remove battery . Reference the Parts Breakdown section of this manual for location .
3 . Wait five minutes for board to de-energize .
4 . With the battery out, re-connect the power supply to the board . The board's display
should begin to show information .
This indicates that the board is operating correctly. If the display does not work, call installing dealer for service.
5 . To replace with new battery, unplug transformer from outlet . Install a 3 volt Lithium Coin Cell type 2032 battery, available at
most stores . Plug unit back into outlet .
It is important to replace the battery with the valve unplugged to avoid causing a short and potentially ruining the board.
6 . Reset the time of day (see programming procedures) and initiate regeneration (see operating displays and maintenance),
If these procedures do not remedy the problem, please consult the installing dealer for service.
6 .
AUDIBLE ALARM:
This control valve is equipped with an audible alarm and visual alarm . This alarm is set by the installing
dealer and is used to warn the owner of possible valve errors or other issues .
To turn off alarm:
If the audible alarm sounds, press any button on the
face of the control valve to turn off and call the dealer for service .
7 .
ERROR MESSAGE:
If the word “ERROR” appears and flashes alternately with the
dealer name and phone number, record the ERROR number and contact your servicing
dealer promptly . This indicates that the control valve was not able to function properly .
MANUAL REGENERATION
REGEN TODAY
MON
GPM
2:40
8
PM
REGEN TODAY
and
TIME OF DAY
will flash alternately if a regeneration
is expected tonight.
BATTERY REPLACEMENT
BACKWASH
8:22
REGENERATION MODE
ERROR
ERROR
106
CALL FOR SERVICE