The following
fi
gure shows an example of paper with the non-thermal paper printed with black marks: the outgoing
voltage is constant while passing the white paper between two notches and presents a peak at each black mark.
In this case, the optimal value for the “Notch Threshold” parameter is placed about half of the peak.
“Notch
Threshold”
NON-THERMAL SIDE
THERMAL SIDE
peak
The following
fi
gure shows an example of paper with the non-thermal paper printed with black marks and other graph-
ics (for example, a barcode): the outgoing voltage is constant while passing the white paper between two notches,
presents a peak at each black mark and presents some “noise” at each barcode.
In this case, the optimal value for the “Notch Threshold” parameter is located about halfway between the peak value
and the maximum value of the “noise”.
NON-THERMAL SIDE
THERMAL SIDE
“Notch
Threshold”
peak
noise
10. ALIGNMENT
86 KPM216HII ETH
User manual
Summary of Contents for KPM216HII-ETH
Page 1: ...OEM Commands manual 77200000000900 KPM216HII ETH KPM216HII ETH USER MANUAL...
Page 6: ...1 INTRODUCTION 6 KPM216HII ETH User manual...
Page 14: ...2 DESCRIPTION 14 KPM216HII ETH User manual...
Page 26: ...3 INSTALLATION 26 KPM216HII ETH User manual...
Page 48: ...5 CONFIGURATION 48 KPM216HII ETH User manual...
Page 53: ...5 Insert the new paper see previous paragraphs 6 MAINTENANCE User manual KPM216HII ETH 53...
Page 64: ...6 MAINTENANCE 64 KPM216HII ETH User manual...
Page 82: ...8 CONSUMABLES 82 KPM216HII ETH User manual...
Page 92: ...10 ALIGNMENT 92 KPM216HII ETH User manual...
Page 94: ...11 TECHNICAL SERVICE 94 KPM216HII ETH User manual...
Page 111: ......