Curtiss-Wright | PG Drives Technology
SK81935-01
72 | R-net Omni2 Technical Manual | Chapter 3 – Programming
Sequence operation with Drive Position Type set to Entry – no beep sequence supported.
Sequence operation with Drive Position Type set to List – beeps will occur when a particular Profile is entered.
Sequence operation with Drive Position Type set to Select – a Profile Select screen, as shown below, will be entered and the
beeps will reflect the selected Profile. Left and right SID movements will select the next available Profiles and the
corresponding number of beeps will occur. To enter the selected Profile, operate the User Switch.
NOTE (HP, IN)
If User Menu Position beeps are also set to occur, they will be issued prior to the Profile Identifier beeps.
NOTE (HP, IN)
It is not advisable to program the menu option, ‘Profile Select’, if the Sequence method is being used with Single Switch
Scanner-Type SIDs.
2.11.6 AXIS IDENTIFIER #
This sets whether a series of beeps, corresponding to the actuator axis number, occurs when that axis is selected.
The programmable options are On and Off.
If set to Off, then no beeps will occur.
If set to On, then upon a change of axis selection, there will be a series of short beeps corresponding to the number of the
newly-selected axis.
NOTE (HP, IN)
If set to On, there will always be an initial short beep to indicate an axis change. There will then be a short pause before the
series of beeps.
If an “Exit” axis is being used (refer to the Actuator Selection section), this is indicated by a single beep of opposite duration to
the beep series.
2.11.7 POSITION 1# TO POSITION 16#
This sets the number of beeps that will occur when each line of the User Menu is highlighted. Because it is possible for the
same item to appear on multiple lines, then the number of beeps is independent from the programmed function.
The programmable range is 0 to 16 in steps of 1.