FILTER - SILENCER (Rotary Blower)
A)
General
:
The air blower filter - silencer is mounted on the air blower. Dirt and
other foreign particles are filtered from the incoming air by means of the reusable
stainless element. The design is such that it partially silences the air also.
Note:
DO NOT
run the machine without this filter silencer assembly, as this would
cause serious damage to the blower unit.
B)
Removal and Disassembly:
1. Remove the filter-silencer from the air blower by turning it counter-clockwise.
2. Remove wing nut and washer.
3. Remove outer shell cover.
4. Remove stainless element.
C)
Inspection and Cleaning:
1. Clean the stainless screen in an approved solvent, dry with compressed air,
or shake to remove excess solvent and allow to dry naturally. Inspect the
screen for defects that may permit dirt or other foreign particles to enter the air
blower.
2. Inspect the outer shell cover for cracks, breaks or dents and replace if
required.
3. Remove any foreign matter of obstruction from any of the tubes of the main
base assembly. Be careful not to lose the clips from the base which isolate the
shell from the base to prevent excessive vibration.
BLOWER FILTER
ASSEMBLY P/N: 62851