Ed. 05421 - 70702561 - REV04 - valid from serial number 21052570 - Giotto - Installation
31
ø 150mm
[5.91 in.]
A
B
C
min 300mm
[11.81 in.
]
Fig. 30.
Fig. 31.
extraction
system
draught
switch
MADE IN ITALY
Mod. GT140/1TS-C5-CP
VOLT
AC
3 -400-50Hz
KW
17,7
2020
S/N GT1401TSC5CP 20020632
Installation
Serial number plate reading
The serial number is on the right hand side of the appliance.
It provides important technical information that is vital in case
of a request for maintenance or repair of the appliance: please
do not remove, damage or modify it.
Smoke extraction
The oven is fitted with an adjustable exhaust in the top to get
rid of the steam from the cooking chamber.
This steam, together with the one from the door during the
work phases,
must be conveyed outside
in one of the fol-
lowing ways:
•
A
through a
hood supplied by the Manufacturer
that
ensures perfect compatibility with the oven. For correct
assembly and fixing to the oven, consult the sheet attached
to it; the evacuation flue must be used only by the appliance,
have a
150 mm
[Ø5.91 in.]
minimum diameter and comply
with the regulations in force.
•
B
through a
hood
belonging to the user, of suitable ca-
pacity, placed at minimum 300 mm [Ø 11.81 in.] from
the oven;
•
C
through an adequate
extraction system
supplied by
the user: in this case a draught switch must be installed
between the extractor and the oven chimney (the extractor
and switch are not supplied by the Manufacturer). In this type
of installation, the fumes resulting from the opening of the
door will not be extracted.
Model
Voltage
Absorption
Year of production
Serial number
Summary of Contents for Giotto GT110
Page 1: ...GT110 GT140 Giotto OVEN Pre installation and installation manual ...
Page 22: ...22 Fig 15 1 7 Installation ...
Page 24: ...24 x2 1 2 17 mm 0 67 in 13mm 0 51 in 1 1 3 3 2 Fig 17 Fig 18 Installation ...
Page 26: ...26 x20 1 3 2 B B B x4 x4 Fig 21 Fig 22 Installation ...
Page 28: ...28 x5 x5 1 1 2 2 3 x4 Fig 25 Fig 26 Installation ...