34
Fig. 36.
Fig. 37.
For a correct electrical connection, the appliance must:
•
be included in an
equipotential system
in compliance
with the legislation in force. This connection must be made
between the various devices with the terminal marked
with the equipotential symbol
. The cable must have
a maximum cross-section of 10 mm2 (in compliance with
IEC EN 60335-2-42:2003-09) and must be yellow-green;
•
must be
grounded
to the mains (green-yellow wire);
•
must be connected to a
thermal differential switch
in
compliance with the regulations in force (0.03A A type);
•
must be connected to an
omnipolar circuit breaker
allow-
ing complete disconnection in overvoltage III category con-
ditions.
The Manufacturer accepts no liability for failure to comply with
the above.
If required, the cable can be replaced by the Dealer or
its technical service or by a person with similar qualifi-
cations to prevent any risk.
Electrical data
Model
Power
supply
(V)
Power
(kW)
Average
consumption
(kWh)
Absorption
(A)
Connection
cable
(Nxmm
2
)
Customer
panel protection
(nxA)
GT 110
GT110/1TS-C5-CP
3Nx400V
16.25
9.7
23.4
5x4
4x25
GT110/1TS-B5-CP
3x230V
40.7
4x10
3x50
GT110/1TS-B6-US
3x208V
41.7
4xAWG7
3x50
GT 140
GT140/1TS-C5-CP
3Nx400V
19.95
11.9
28.7
5x4
4x32
GT140/1TS-B5-CP
3x230V
50.0
4x10
3x50
GT140/1TS-B6-US
3x208V
50.3
4xAWG7
3x63
Summary of Contents for Giotto GT110
Page 1: ...GT110 GT140 Giotto OVEN Pre installation and installation manual ...
Page 22: ...22 Fig 15 1 7 Installation ...
Page 24: ...24 x2 1 2 17 mm 0 67 in 13mm 0 51 in 1 1 3 3 2 Fig 17 Fig 18 Installation ...
Page 26: ...26 x20 1 3 2 B B B x4 x4 Fig 21 Fig 22 Installation ...
Page 28: ...28 x5 x5 1 1 2 2 3 x4 Fig 25 Fig 26 Installation ...