Part No. 4801-5120 Rev. 1-2020
Mega-Cool System
Page 37 of 48
INSTRUCTIONS - Connect Pump to Spray Line
NOTE: The total vertical height of pipe sections in the
following instructions must reach from Sump Pump to
level of spray line. Adjust lengths of pipe sections as
required for proper height. For proper alignment, cut
and assemble all pieces of pipe and fittings before
gluing together.
1. Cut pieces of 1 ½" pipe supplied to lengths needed and glue
together with appropriate fittings called out as shown at the
left. When cutting pieces of 1 ½" pipe, notice that the pump
supply line must rest in slotted pipe and align with 8" pipe as
shown.
2. Next, assemble remaining supply line assembly as shown at
the left using fittings called out and 1 ½" pipe supplied. Cut 1
½" pipe into necessary lengths required. When gluing all
pieces together be sure that bottom part of supply line
assembly containing filter is rotated to properly align and
connect with pump supply line extending from slotted pipe at
top of Tee-Tank assembly.
3. Once assembled, align and connect all supply lines as shown
on Pages 33 and 34.
Sump Pump Side View
Filter
12”PVC
Cap
1 ½" 90º
Elbow
Threaded
Union
12"x12" Pipe with cut
channel
12"x8" Tee
12"
Bottom Cap
12"x3'
Reservoir
and Pump
1 ½" to 1"
Reducing Tee
1 ½" Ball Valve
(Primary Flow
Regulator)
1 ½" 90º
Elbow
½"x90º
Elbow
Drain Support
Bracket
1" Ball Valve
NOTE: The Pump housing is designed to be installed below ground level.