Manual No. 4801- 2997 Rev 1-15
Secondary Sensing System
6 of 42
Secondary Sensing System Front Panel
Control / Editor
Section
Back-Up Section
Zone Temperature
Section
Synchronize / Test
Section
Power Switch
Alarm Status
Section
4.
S
3
Front Panel
The
S
3
has five main sections on the faceplate. These are the Zone Temperature Section, the Back-Up Section, the
Control / Editor Section, the Synchronize / Test Section, and the Alarm Status Section.
The
S
3
Power Switch is located on the left side of the controller box as shown below. The switch controls power to
the
S
3
controller and to the back-up battery.
4.1
Control / Editor Section
Just below the Back-Up Section on the right hand side of the controller is the
Control / Editor Section
.
This section has three buttons:
Mode, Plus (+) and Minus (–)
. The
Mode
button is used to navigate thru
settings and conditions. When the Mode button is momentarily pressed, the green LED Indicators changes
to the next reading. By pressing and holding the
Mode
button for at least 5 seconds, the
S
3
can be placed
in the
Program Mode
as discussed in
Section 5
of this manual. Press the
Plus (+) or Minus (-)
button to
change the values (readings) in the Ventilation Back-Up Display or Zone Temperature Section Displays
depending on the specific display selected.
Control / Editor Green Indicator LED’s show the type of information represented. For example, if the
green light beside “Temperature” is lit, then the Zone Displays are showing the current readings from
sensors. The other options for the Display Indicators are Target, High Limit, Low Limit, Status, and
History. These modes are changed by momentarily pressing the Mode button. Each press of the Mod
e
button steps the Display Indicator to the next reading Mode.
LED
Indicators
+ Scroll
Button
-
Scroll
Button
Mode
Button