Manual No. 4801- 2997 Rev 1-15
Secondary Sensing System
9 of 42
4.1.5 Status
The
Status Mode
displays the Sensor Status (ON or OFF) for each specific zone. This setting is used to
remove unused sensors or to deactivate sensors outside of the brood area during ½ or ¾ brood conditions.
Use the
Zone Switches
for selecting the specific Zone Temperature Sensor then using the
+ (ON) or –
(OFF) buttons
to enable or disable sensors.
4.1.6 History
The
History Mode
displays the High and Low Temperatures for each specific zone, any Back-Up stages
which have turned ON, as well as any alarm conditions which have occurred since the last reset.
The
History Reset
function is displayed after pressing the Mode Button once after the Low Temp is
displayed. The Zone 1 display will indicate “
HIS
” and the Zone 2 display will indicate “no” initially.
Press the “+” button for selecting YES, then press the Mode button to confirm the History Reset to reset all
control history. A new feature added in version V0.10 and later software allows automatic resetting of the
on-board history anytime the Synchronize button is pressed.
Status for Specific Zones
Zone Switches
Status for Specific Zones
(High or Low Temperature Mode)
Temperatures for
Specific Zones
High Temp
Low Temp
Reset
Press
Display History Selection Sequence
Press