60
Culligan® Premier Series Automatic Deionizer
60
Cat. No. 01024000
Pre-Fast Rinse Anion
The Pre-Anion Fast Rinse step allows the anion to rinse at full flow rate, clearing out the caustic that has settled in the
piping. The Cation Backwash Inlet Valve (C1), Backwash Inlet valve (A1), and Anion fast rinse valve (A6) remain open.
C1
C4
A5
C2
A3
A1
A2
A4
C3
A6
C5
CP
AP
PR
2
TO
NEUTRALIZATION
TANK
Figure 24.
Pre-fast rinse anion cycle.