90
Culligan® Premier Series Automatic Deionizer
90
Cat. No. 01024000
Programming the External Flow Meter
An optional Flow Meter can be used in the system outlet to trigger a regeneration. This requires an entry in the program-
ming for the meter chosen. The entry is pulses per gallon, or K Factor. See
"Flow Device K-Factor Data" on page 81
.
SERVICE
FEB-01-13 12:11P
10.0GPM 161PPM
1. From the default home screen, press
to display the main menu.
2)MANUAL REGEN
3)SET DATE/TIME
4)ADV. SETUP
>5)ACCESSORIES
2. From the main menu screen, press
to 5)ACCESSORIES.
3. Press
. The screen displays the Accessories menu.
>1)TDS
2)FLOW METER
4. Press
to select 2)FLOW METER
.
The screen displays the flow meter
settings.
FLOW METER
>INSTALLED
5. The default setting is INSTALLED. Press
to view the flow meter settings.
FM1 K FACTOR
80.0
PULS/GAL
6. The screen displays the specified pulses per gallon (K Factor) for the optional flow
meter (if purchased and installed). This value does not need to be set. Press
and
or
and
to change the setting and return to the Accessories menu.
See
"Appendix C Flow Device K-Factor Data" on page 81
for more information.
SERVICE
FEB-01-13 12:11P
10.0GPM 161PPM
7. Press
until the deionizer controller displays the home screen.
External Flow Meter Set-Point Adjustment
1. Turn on the Power and press the SET button; the display will show the default of previously adjusted value,
along with the SET indicator.
2. Use a small screwdriver to adjust the SET trimmer pot until the desired set-point value is displayed. The
instrument will automatically returns to the normal measurement mode after 1 minute, or if the MEAS button is
pushed.
Setup If No Flow Meter Is Installed
2)MANUAL REGEN
3)SET DATE/TIME
4)ADV. SETUP
>5)ACCESSORIES
1. From the main menu screen, press
to 5)ACCESSORIES.
2. Press
. The screen displays the Accessories menu.
1)TDS
>2)FLOW METER
3. Press
to select 2)FLOW METER
.
The screen displays the flow meter
installation settings.
FLOW METER
>NOT INSTALLED
4. The default setting is INSTALLED. Press
and
or
to change the set-
ting to NOT INSTALLED and return to the Accessories menu.