SET-UP & INSTALLATION
COUNT DIRECTION
UP
DOWN
COUNT DIRECTION
COILER TYPE
WARNING: ALL CABLE MUST
BE IN BEFORE PROCEEDING!
STANDARD BASKET
XL BASKET
AUXILIARY REEL
COILER TYPE
• The selection of ‘XL’ as the Coiler Type automatically selects large cable, internally.
• The combinations of large coiler with standard cable and standard coiler with large cable
are invalid and are currently not selectable.
• Changing the coiler type requires an internal reset of the distance calculation firmware,
which requires that all of the cable be retracted into the coiler for the distance to count
properly.
• Proper PICS operation requires selection of “STANDARD” coiler.
Count direction refers to whether the footage counts up or down when the cable is pulled out.
AUX. REEL SCALING COUNT
004000 counts per 100 ft
----- DEFAULT VALUES -----
IGGY : 004000
AUX REEL SCALING COUNT
When using an auxiliary reel, the scaling counts must be input in order for the distance to
count properly.
• AUX REEL SCALING COUNT