CTC 380 IC
9
3. Technical data
3.1 Technical data
CTC 380 IC
17
19
24
29
Rated input
kW
17,8
19,7
24,5
29,3
Rated output 50/30 °C
kW
18,2
20,1
25,0
29,9
Rated output 80/60 °C
kW
17,2
19,0
23,7
28,3
Oil supply
g/h
1190
1330
1680
2030
Flue gas mass flow rate
g/s
6,08
6,80
8,59
10,38
Boiler water resistance (
∆Τ
20
Κ
)
mbar
95
125
175
160
Boiler efficiency 50/30 °C
%
102
102
102
102
Flue gas temperature 50/30 °C
°C
44
44
44
43
Flue gas temperature 80/60 °C
°C
60
61
61
62
Max boiler operating pressure
bar
3
3
3
3
Max operating temperature
°C
110
110
110
110
Water content
l
98
98
92
93
Weight
kg
239
239
248
251
Number of flue gas heat exchangers
units
1
1
1
2
Number of turbulators.
units
6
6
9
9
Turbulator type
27/45 XS
27/45 XS
27/45 XS
27/45 XS
Electric data
230V 1
N~
230V 1
N~
230V 1
N~
230V 1
N~
Oil burner type
BF1 M1V
BF1 M1V
BF1 M1V
BF1 M1V