Operation / Technical Manual
NORM-O-TEMP
®
, Model 111W
Page 59 of 82
P.
Secure the three-sided enclosure panel as described in Section 6-1.4.
Q.
Refill the water reservoir as described in Section 5-1.5.
6-13.
Replacement of the Power Switch
A.
Obtain the replacement power switch.
B.
Drain the reservoir as described in Section 5-1.4.
C.
Remove the three-sided enclosure panel as described in Section 6-1.3.
D.
Locate the power switch on the front left side of the unit as shown in Figure
E.
Press together the tension clips on the top and bottom of the switch
assembly by reaching inside the unit from the right side. Push the switch
out through the opening in the enclosure.
F.
Disconnect the four slide-on connectors from the switch. Note which wire
goes to which terminal. Remove and discard the old power switch.
G.
Position the replacement power switch into the unit in the same manner
and position as the one you removed. Reconnect wires as noted above.
H.
Secure the three-sided enclosure panel as described in Section 6-1.4.
6-14.
Replacement of the Water Level Sensor Assembly
A.
Obtain a replacement water level sensor.
B.
Remove the top of the unit as described in Section 6-1.1.
C.
Locate the water level sensor. Facing the unit, it is a square, grey plate
located in the center as shown in Figure 9.
D.
Disconnect the water level sensor.
E.
Using a 5/16 inch wrench, remove the four nuts from the screw post in the
four corners of the water level sensor.
F.
Remove the water level sensor and discard. Make sure the black gasket
remains on the four posts.
G.
Insert the replacement water level so that the holes are aligned with the
four screws posts.