Operation / Technical Manual
NORM-O-TEMP
®
, Model 111W
Page 55 of 82
J.
Attach and tighten the male couplings to the water manifold. Make sure the
copper elbow points down.
K.
Reconnect the by-pass line and replace the cable ties.
L.
Connect the hose from the pump housing to the copper elbow of the
manifold and tighten the clamp.
M.
Remove the used white teflon tape from around the threads of the water
temperature sensor and apply new Teflon tape.
N.
Reinsert the water temperature sensor as described in Section 6-6.
O.
Secure the three-sided enclosure panel as described in Section 6-1.4.
P.
Refill the reservoir as described in Section 5-1.5.
6-7.2.
Return Manifold
A.
Collect the required tools.
1. 9/16 inch wrench, pliers, phillips screwdriver
2. Teflon tape
3. Replacement of the water return manifold.
B.
Drain the reservoir as described in Section 5-1.4.
C.
Remove the three-sided enclosure panel as described in Section 6-1.3.
D.
Locate the (top) manifold to be replaced which is secured to the left side of
the unit behind the water pump, shown in Figure 9. The manifold is
connected to the female quick disconnect fittings and to the water flow
indicator via a 5½ inch piece of clear tubing.
E.
Disconnect the hose by loosening the clamp around the copper elbow of the
manifold.
F.
Remove the two female quick disconnect fittings from the outside of the
unit using the 9/16 inch wrench.
G.
Remove the old manifold from the unit. Remove the washers from the old
manifold and install onto the new manifold. Apply Teflon tape around the
threads of the new manifold and be careful not to block the openings.
Discard the old manifold.