Bradford NCC2019 Performance Solution
The Bradford NCC2019 Performance Solution provides an alternate method to
comply with the Deemed-To-Satisfy
roof ventilation
requirements listed in
NCC2019 Volume 1 Clause F6.4 and NCC2019 Volume 2 Clause 3.8.7.4
Please note, c
ompliance with the NCC2019 is only mandatory for
new build
residential homes, and
may
not apply to reroof, or installation onto existing homes.
How To Comply with NCC2019 Performance Solution
To comply, the installation of both
Maestro BAL
and Metal Eave vents are required
.
The number of
Maestro BAL
and Metal Eave vents required is determined by the
ceiling size directly under the roof space of the home
.
General requirements for implementation of this performance solution
•
Calculate the area (m2) of ceiling directly under the roof space;
•
Install
Maestro BAL
(s) running at 30% power
^
according to the table below
•
Install Bradford metal eave vents according to
the table below
Note: Bradford metal eave vents cannot be substituted for any other type of eave vent
including poly eave vents due to th
e
specific
openess factor required.
•
Distribute the metal eave vents evenly as per NCC2019
^All
Maestro BAL
are default set to a continuous 30% fixed speed. To comply with NCC2019 Performance
Solution this setting must not be changed. See Page 4 for more details.