STEP 10
Remove the ventilator
and cut a 300mm
square or round opening
around the centre of the
position marks.
Turn up the corrugations
or pans on both the low
and high sides. This will
help to prevent water
ingress.
TURN UP
TURN UP
Installation -
Metal Roof
STEP 11
Return the Maestro BAL
to the roof, positioning
it over the cutout.
Ensure that the top of
the flashing is slipped
under the ridge capping.
For lower pitched roofs,
turn up the top edge
of the flashing before
slipping under ridge
capping. This will help
prevent water ingress.
For BAL compliance, no gaps greater than
2mm
may be
present. A water tight install can be achieved by carefully
forming the
flashing to the roof sheeting profile, without the use
of sealant.
14
Summary of Contents for Bradford Maestro BAL
Page 1: ...Product Manual ...
Page 3: ...3 4 1 2 3 ...
Page 25: ...25 Notes ...
Page 26: ...26 Notes ...
Page 27: ...bradfordventilation com au ...