Installation -
Tiled Roof
Turning the rear of the flashing upwards
allows it to act as a gutter to prevent any
wind driven water from entering the roof
space.
FLASHING UPSTAND
FIXING STRAP
SCREW/NAIL
BATTEN
STEP 8
Form the fixing strap so
that one end can hook
over the f
ashing upstand
From within the roof
space, hook the fixing
strap over the edge of the
f
ashing upstand at the
lowest point of the roof.
Screw/nail (not supplied)
the fixing strap to the
bottom batten to securely
hold the ventilator down.
For additional weather
proofing turn the rear
edge of the f
l
ashing up so
that
it seals against the
tiles above.
PROCEED TO ELECTRICAL CONNECTION
*Important Note*
If using the
Maestro BAL t
o comply with NCC2019
Performance
Solution
a
dditional
Maestro
BAL's
and eave
vents may be
required depending on
the
ceiling area of the
home. For more
information on
the number of
Maestro BAL
and
eave vents
required
see Page 7 of this manual or
visit
bradfordventilation
.com.au
Installing an eave vent
Mark a 185mm x 385mm rectangle
on the eave lining
Drill holes to mark out the rectangle
Use a hacksaw to cut out the
rectangle
Attach the vent using the screw
provided