Installation -
Metal Roof
STEP 9
Select a suitable position for
the ventilator.
Slip the top edge of the
flashing under the ridge cap
and mark position.
To Install the vent lower
down the roof, appropriate
backflashing must be
installed, extending back to
the ridge capping.
Ensure that the flashing covers the roof corrugations or ribs
equally and that it is located between roof rafters.
MARK CENTRE
Note:
Ridge capping screws may need to be removed whilst performing
installation. Upon completion, return the fixing screws to the previous positions
*Note*
If installing in accordance with the NCC 2019 Performance
Solution,
the
Maestro BAL
must be located not more than 900mm below the
ridge or
the
highest point of the roof space when measured vertically.