5.
MAINTENANCE
Regular maintenance of this product is essential to ensure its safe and long-term operation. It is the
responsibility of the building owner or manager to outline the maintenance program throughout the
product’s lifespan. The following components should be inspected on a regular basis:
WARNING: Prior to inspecting the ventilator ensure that the power is turned off and that the ventilator head
is held in a static position by another person using a gloved hand on the top surface of the turbine (away
from the turbine blades) – this should not be undertaken on a windy day when the turbine head cannot be
safely slowed.
•
Rotating/turbine head – check for excessive movement/contact between components, unusual noise
during rotation, listen for noises and assess visual wear & tear.
•
Fasteners – check all are in situ and well-sealed.
•
Flashing Connections – check joints that are meant to be sealed remain sealed and that those that
are meant to be unsealed are clear of obstruction.
•
Pestguard (if provided) – ensure this is clear of debris.
•
Electrical component and connections – check connections for wear or exposure damage.
6.
TROUBLESHOOTING GUIDE
No Failure Mode / Potential Cause(s)
Image / Description
1 Issue: Water or rain leakage
Potential Cause: Varipitch connection not sealed.
Action: Seal Varipitch connection with flexible,
weatherproof sealant.
Additional Information: The photo in the sidebar shows
the possible outcome if the Varipitch connection has
been slightly separated during angle adjustment or has
not been sealed.
2 Issue: Water or rain leakage
Potential Cause: Ventilator throat gutter blocked.
Action: Remove blockage – refer drainage diagram in
these instructions
Additional Information: Placing sealant around the bottom
of the vent throat where it contacts the flashing blocks
the vent gutter at the base of the throat, preventing the
release of internal condensation and mist from the inside
of the throat.