background image

14 

The contents of this install guide are copyright protected and may not be reproduced in any form without prior written consent of CSR. Recommendations and  
advice regarding the use of the products described in this guide are to be taken as a guide only, and are given without liability on the part of the company or 
its employees. We reserve the right to change product specifications without prior notification, please refer to the CSR website for the latest version of this 
document. The purchaser should independently determine the suitability of the product for the intended use and application.

 

 

Important Note Regarding Roof Structural Support

:  

EP400 - EP600 & H100 – H600

 – If the purlin spacing is larger than 600mm, trimmers are 

required. Install the trimmers between the purlin on either side of the opening. Do not cover the 
openings. 

EP900 & H700 – H900 

– If the purlin spacing is larger than 1000mm, trimmers are required. 

Install the trimmers between the purlin on either side of the opening. Do not cover the opening. 

 

 

 

 

 
 

Purlin

 

Flashing

 

Summary of Contents for Bradford EcoPower 400

Page 1: ...Industrial Ventilators Installation Instructions EcoPower and Hurricane Non Cyclonic PRINT IN COLOUR V3 0 08 22...

Page 2: ...met Product Make up air per ventilator 100 open evenly distributed open area Allowable Roof Pitch EcoPower 400 Hurricane 100 400 0 3m up to 45 EcoPower 600 Hurricane 450 600 0 5m up to 45 EcoPower 90...

Page 3: ...cument The purchaser should independently determine the suitability of the product for the intended use and application b SUPPLEMENTARY FLASHING required for installation away from the ridge refer to...

Page 4: ...ation products must be installed by a qualified installer and all electrical wiring where applicable must be undertaken by a qualified electrician d EcoPower Hybrid Ventilators use 220V 240V AC power...

Page 5: ...that the ventilators are not sheltered from the wind by surrounding objects the shadow angle created by the roof ridge or by each other Make up air is required for this ventilator to replenish the exh...

Page 6: ...ation please refer to the CSR website for the latest version of this document The purchaser should independently determine the suitability of the product for the intended use and application 3 INSTALL...

Page 7: ...please refer to the CSR website for the latest version of this document The purchaser should independently determine the suitability of the product for the intended use and application Important Note...

Page 8: ...purchaser should independently determine the suitability of the product for the intended use and application b Cut Hole Carefully cut the hole remembering that there may be insulation and other roof...

Page 9: ...ently determine the suitability of the product for the intended use and application d Assemble the Varipitch When a Varipitch throat is being used position the Varipitch on the flashing and rotate the...

Page 10: ...of this document The purchaser should independently determine the suitability of the product for the intended use and application e Secure the Varipitch Angle With the Varipitch upper throat positione...

Page 11: ...urbine head to the Varipitch Re check if the assembly is level horizontal and adjust the turbine by tilting the throat slightly if required Ensure the knurling the tapered section of the Varipitch is...

Page 12: ...latest version of this document The purchaser should independently determine the suitability of the product for the intended use and application i Sealing is crucial for this product to ensure no leak...

Page 13: ...ct specifications without prior notification please refer to the CSR website for the latest version of this document The purchaser should independently determine the suitability of the product for the...

Page 14: ...please refer to the CSR website for the latest version of this document The purchaser should independently determine the suitability of the product for the intended use and application Important Note...

Page 15: ...etermine the suitability of the product for the intended use and application b Cut Hole Carefully cut the hole remembering that there may be insulation and other roof members under the roof sheet Once...

Page 16: ...please refer to the CSR website for the latest version of this document The purchaser should independently determine the suitability of the product for the intended use and application Model Fasteners...

Page 17: ...purchaser should independently determine the suitability of the product for the intended use and application d Assemble the Varipitch When a Varipitch throat is being used position the Varipitch on t...

Page 18: ...est version of this document The purchaser should independently determine the suitability of the product for the intended use and application f Weather Sealing Seal the Varipitch seam on the inside wi...

Page 19: ...ine Assemble the turbine head to the Varipitch Re check if the assembly is level horizontal and adjust the turbine by tilting the throat slightly if required Ensure the knurling the tapered section of...

Page 20: ...his document The purchaser should independently determine the suitability of the product for the intended use and application i Sealing is crucial for this product to ensure no leaking occurs during i...

Page 21: ...e undertaken on a windy day when the turbine head cannot be safely slowed Rotating turbine head check for excessive movement contact between components unusual noise during rotation listen for noises...

Page 22: ...ch allows rain bounce to drive water off roof into ventilator Action Install recommended ventilator throat 6 Issue Condensation Drip after hours for ventilator with damper Potential Cause Inadequate m...

Page 23: ...nd giving the appearance of a leak The characteristics of this phenomenon occur when a The building is very air tight and make up air is not balanced b Vents are located at different levels on the roo...

Reviews: