16
The contents of this install guide are copyright protected and may not be reproduced in any form without prior written consent of CSR. Recommendations and
advice regarding the use of the products described in this guide are to be taken as a guide only, and are given without liability on the part of the company or
its employees. We reserve the right to change product specifications without prior notification, please refer to the CSR website for the latest version of this
document. The purchaser should independently determine the suitability of the product for the intended use and application.
Model
Fasteners to
secure turbine
flashing to roof
EcoPower 400
Hurricane 100
- 400
12 (4 near throat)
EcoPower 600
Hurricane 450
- 600
18 (4 near throat)
EcoPower 900
Hurricane 700
- 900
26 (4 near throat)
Use 10G X 16MM Galvanised Self Drilling
TEK Screws with Neoprene Washer or
5/32" (4.0mm) Rivets Aluminium/Steel
Sealed
Extended Flashing
(not supplied)
Overlap requirement between extended
flashing and turbine flashing is 100mm to
250mm.