HV Breakout Module – Appendix
Installation Manual
42
Version 01.20 // 2021
Fig. 7-16: Step 5: Attaching and fixing the shrink sleeve
"
Slide a 10 mm long piece of shrink sleeve over the HV power cable up to
the marking (Fig. 7-15).
"
Fix the shrink sleeve by applying heat.
Fig. 7-17: Step 6: Dismantling the inner sheath
"
Remove the grey inner sheath over a length of 30 mm.
⇨
A red and a black wire will appear.
Fig. 7-18: Step 7: Dismantling the red and black wire
"
Dismantle both wires over a length of 8 mm.
Fig. 7-19: Step 8: Attaching and fixing the ring terminal
"
Slide 12 mm long pieces of shrink sleeve onto the red and the black wire.
"
Attach M8 ring terminals to the dismantled wires.
18
"
Use the crimping pliers to crimp the ring terminals and then solder them.
"
Slide the shrink sleeves over the ring terminals, so that they cover the
crimped terminal ends and the red or black wire by 6 mm each.
"
Fix the shrink sleeve by applying heat.
→ For information on how to connect the HV power cables to the measurement module,
please refer to chapter 4.3.3.3 "HV BM 1.x: Connecting the HV power cables".
18 As of hardware revision E, M8 ring terminals are used for both wires. For hardware revision A, an M6 ring terminal is used for
the red wire instead of an M8 ring terminal.