USER'S MANUAL, VERSION 2.0
Copyright © Convergence Systems Limited 2021, All Rights Reserved
228
Add Resultant Action
There are 8 types of possible action:
1.
Do Nothing (Only Show on Screen) – here nothing is affected, except the tags collected can
be shown on browser screen. Note that there are APIs that can collect the tag IDs or
information on demand from the remote server. So this is actually a polling mode in
terms of collecting tag information.
2.
Batch Alert to Server – here the collected tag information are sent to Server at the end of
each duplicate elimination cycle (Time Window)
3.
Instant Alert to Server – here the collected tag information are sent to Server immediately
as it is read.
4.
Low Latency Alert to Server
5.
Output Port – here the General Purpose IO output port would be controlled to have certain
level change or pulse or even pulse train.
6.
Save to External USB Memory – here the tag information was sent to external USB flash
memory.
7.
Display Tag Database Record
8.
Display Tag Group Record