USER'S MANUAL, VERSION 2.0
Copyright © Convergence Systems Limited 2021, All Rights Reserved
275
9.4
Example 2: Traffic Control
– Management of
Traffic at Building Entrance
Define two events to manage the Truck/Personnel In and Out, one event for
incoming called “Example Event Entrance Boom Barrier Control”, while another
event for outgoing called “Example Event Exit Boom Barrier Control”, also those
two event is exclusive since the system should not handle the Entrance/Exit
simultaneously. Also, two antenna was used in this example, ensure antenna was
connected both on Antenna Port 1 and Port 2 before enable the example event
mentioned on following section
For incoming personnel case, the Tigger “Infrared Sensor GP1 Port 1 High” is used
to detect incoming personnel then start inventory, this personnel leaving is detected
by “Infrared Sensor GP1 Port 2 High” then stop inventory.
For leaving personnel case, the Tigger “Infrared Sensor GP1 Port 2 High” is used to
detect leaving personnel then start inventory, the personnel going out is detected by
“Infrared Sensor GP1 Port 1 High” then stop inventory.