18
MAB 465
GB
Troubleshooting
Troubleshooting
Error
Possible cause
Remedy
The motor does not start after
pressing the ON/OFF switch
or stops during operation.
Plug not inserted into socket.
Insert plug.
Circuit breaker switched off.
Switch on circuit breaker.
The magnetic clamp is not
switched on.
Switch on the magnetic clamp.
Direction of rotation not
selected.
Select direction of rotation.
The internal safety switch has
switched off the machine due
to overheating.
Allow the machine to cool
down.
The torque cut-off has tripped. Switch the machine off and on
again.
The circuit breaker in the
power distributor trips.
Too many appliances connect-
ed to the same power circuit.
Reduce the number of appli-
ances on the power circuit.
The machine is defective.
Contact customer service.
The magnetic clamp does not
function.
Magnet not switched on.
Switch on the magnet.
The surface is not magnetic.
Use a suitable base.
The lubrication system does
not function.
No lubricant available.
Top up the lubricant.
Lubricant tap closed.
Open the lubricant tap.
Connecting nipple clogged.
Clean the tank and nipple.
NOTE
►
If you cannot resolve the problem with the steps described above, please contact
customer service.
WWW.CSUNITEC.COM